Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2012 Nov-Dec;19(6):1003-10.
doi: 10.1136/amiajnl-2011-000730. Epub 2012 Jun 26.

Failure to utilize functions of an electronic prescribing system and the subsequent generation of 'technically preventable' computerized alerts

Affiliations

Failure to utilize functions of an electronic prescribing system and the subsequent generation of 'technically preventable' computerized alerts

Melissa T Baysari et al. J Am Med Inform Assoc. 2012 Nov-Dec.

Abstract

Objectives: To determine the frequency with which computerized alerts occur and the proportion triggered as a result of prescribers not utilizing e-prescribing system functions.

Methods: An audit of electronic inpatient medication charts at a teaching hospital in Sydney, Australia, was conducted to identify alerts fired, to categorize the system functions used by prescribers, and to assess if use of short-cut system functions could have prevented the alerts.

Results: Of the 2209 active orders reviewed, 600 (27.2%) triggered at least one alert. Therapeutic duplication alerts were the most frequent (n=572). One third of these (20.2% of all alerts) was 'technically preventable' and would not have fired if prescribers had used a short-cut system function to prescribe. Under-utilized system functions included the option to 'MODIFY' existing orders and use of the 'AND' function for concurrent orders. Pregnancy alerts, set for women aged between 12 and 55 years, were triggered for 43% of drugs ordered for this group.

Conclusion: Developers of decision support systems should test the extent to which technically preventable alerts may arise when prescribers fail to use system functions as designed. Designs which aim to improve the efficiency of the prescribing process but which do not align with the cognitive processes of users may fail to achieve this desired outcome and produce unexpected consequences such as triggering unnecessary alerts and user frustration. Ongoing user training to support effective use of e-prescribing system functions and modifications to the mechanisms underlying alert generation are needed to ensure that prescribers are presented with fewer but more meaningful alerts.

PubMed Disclaimer

Conflict of interest statement

Competing interests: None.

Figures

Figure 1
Figure 1
Doctor's prescribing screen displayed when the prescriber selects Metformin (500 mg) Modified Release Tablet from the product list.
Figure 2
Figure 2
Computerized alert. Two alerts (a local message and ‘Substance Duplication’) were triggered in response to Ceftriaxone being selected.

Comment in

Similar articles

Cited by

References

    1. Bates DW, Leape LL, Cullen DJ, et al. Effect of computerized physician order entry and a team intervention on prevention of serious medication errors. JAMA 1998;280:1311–16 - PubMed
    1. Reckmann MH, Westbrook JI, Koh Y, et al. Does computerized provider order entry reduce prescribing errors for hospital inpatients? A systematic review. J Am Med Inform Assoc 2009;16:613–23 - PMC - PubMed
    1. Chaudhry B, Wang J, Wu S, et al. Systematic review: impact of health information technology on quality, efficiency, and costs of medical care. Ann Intern Med 2006;144:742–52 - PubMed
    1. Westbrook JI, Reckmann M, Li L, et al. Effects of two commercial electronic prescribing systems on prescribing error rates in hospital in-patients: a before and after study. PLoS Med 2012;9:e1001164. - PMC - PubMed
    1. Zhan C, Hicks RW, Blanchette CM, et al. Potential benefits and problems with computerized prescriber order entry: analysis of a voluntary medication error-reporting database. Am J Health-System Pharm 2006;63:353–8 - PubMed

Publication types