Understanding and preventing wrong-patient electronic orders: a randomized controlled trial
- PMID: 22753810
- PMCID: PMC3638184
- DOI: 10.1136/amiajnl-2012-001055
Understanding and preventing wrong-patient electronic orders: a randomized controlled trial
Abstract
Objective: To evaluate systems for estimating and preventing wrong-patient electronic orders in computerized physician order entry systems with a two-phase study.
Materials and methods: In phase 1, from May to August 2010, the effectiveness of a 'retract-and-reorder' measurement tool was assessed that identified orders placed on a patient, promptly retracted, and then reordered by the same provider on a different patient as a marker for wrong-patient electronic orders. This tool was then used to estimate the frequency of wrong-patient electronic orders in four hospitals in 2009. In phase 2, from December 2010 to June 2011, a three-armed randomized controlled trial was conducted to evaluate the efficacy of two distinct interventions aimed at preventing these errors by reverifying patient identification: an 'ID-verify alert', and an 'ID-reentry function'.
Results: The retract-and-reorder measurement tool effectively identified 170 of 223 events as wrong-patient electronic orders, resulting in a positive predictive value of 76.2% (95% CI 70.6% to 81.9%). Using this tool it was estimated that 5246 electronic orders were placed on wrong patients in 2009. In phase 2, 901 776 ordering sessions among 4028 providers were examined. Compared with control, the ID-verify alert reduced the odds of a retract-and-reorder event (OR 0.84, 95% CI 0.72 to 0.98), but the ID-reentry function reduced the odds by a larger magnitude (OR 0.60, 95% CI 0.50 to 0.71).
Discussion and conclusion: Wrong-patient electronic orders occur frequently with computerized provider order entry systems, and electronic interventions can reduce the risk of these errors occurring.
Conflict of interest statement
Figures
Similar articles
-
Effect of Restriction of the Number of Concurrently Open Records in an Electronic Health Record on Wrong-Patient Order Errors: A Randomized Clinical Trial.JAMA. 2019 May 14;321(18):1780-1787. doi: 10.1001/jama.2019.3698. JAMA. 2019. PMID: 31087021 Free PMC article. Clinical Trial.
-
Intercepting wrong-patient orders in a computerized provider order entry system.Ann Emerg Med. 2015 Jun;65(6):679-686.e1. doi: 10.1016/j.annemergmed.2014.11.017. Epub 2014 Dec 18. Ann Emerg Med. 2015. PMID: 25534652 Free PMC article.
-
Wrong-Patient Orders in Obstetrics.Obstet Gynecol. 2021 Aug 1;138(2):229-235. doi: 10.1097/AOG.0000000000004474. Obstet Gynecol. 2021. PMID: 34237762
-
Just what the doctor ordered. Review of the evidence of the impact of computerized physician order entry system on medication errors.Health Serv Res. 2008 Feb;43(1 Pt 1):32-53. doi: 10.1111/j.1475-6773.2007.00751.x. Health Serv Res. 2008. PMID: 18211517 Free PMC article. Review.
-
Reduction in medication errors in hospitals due to adoption of computerized provider order entry systems.J Am Med Inform Assoc. 2013 May 1;20(3):470-6. doi: 10.1136/amiajnl-2012-001241. Epub 2013 Feb 20. J Am Med Inform Assoc. 2013. PMID: 23425440 Free PMC article. Review.
Cited by
-
Risk factors for wrong-patient medication orders in the emergency department.JAMIA Open. 2024 Oct 25;7(4):ooae103. doi: 10.1093/jamiaopen/ooae103. eCollection 2024 Dec. JAMIA Open. 2024. PMID: 39464798 Free PMC article.
-
Diagnostic Errors in Obstetric Morbidity and Mortality: Methods for and Challenges in Seeking Diagnostic Excellence.J Clin Med. 2024 Jul 20;13(14):4245. doi: 10.3390/jcm13144245. J Clin Med. 2024. PMID: 39064285 Free PMC article. Review.
-
Association of patient photographs and reduced retract-and-reorder events.JAMIA Open. 2024 Jul 2;7(3):ooae042. doi: 10.1093/jamiaopen/ooae042. eCollection 2024 Oct. JAMIA Open. 2024. PMID: 38957593 Free PMC article.
-
Retrospective cohort study of wrong-patient imaging order errors: how many reach the patient?BMJ Qual Saf. 2024 Jan 19;33(2):132-135. doi: 10.1136/bmjqs-2023-016162. BMJ Qual Saf. 2024. PMID: 38071526 Free PMC article.
-
Automated search methods for identifying wrong patient order entry-a scoping review.JAMIA Open. 2023 Aug 2;6(3):ooad057. doi: 10.1093/jamiaopen/ooad057. eCollection 2023 Oct. JAMIA Open. 2023. PMID: 37545981 Free PMC article. Review.
References
-
- United States Department of Labor. United States Bureau of Labor Statistics. Occupational outlook handbook, 11th edn 2010. http://www.bls.gov/oco/pdf/ocos074.pdf (accessed 2 Jul 2011).
-
- Davis MW. The State of US Hospitals Relative to Achieving Meaningful Use Measurements. HIMSS Analytics. 2009. http://www.himssanalytics.org/docs/HA_ARRA_100509.pdf (accessed 2 Jul 2011).
-
- U.S. Department of Health & Human Services. Press Release. 2011. http://www.hhs.gov/news/press/2011pres/01/20110113a.html (accessed 2 Jul 2011).
-
- Bates DW, Leape L, Cullen DJ, et al. Effect of computerized physician order entry and a team intervention on prevention of serious medication errors. JAMA 1998;280:1311–16 - PubMed
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical