Lingual electrotactile stimulation as an alternative sensory feedback pathway for brain-computer interface applications

J Neural Eng. 2012 Aug;9(4):045007. doi: 10.1088/1741-2560/9/4/045007. Epub 2012 Jul 25.

Abstract

This article describes a new method of providing feedback during a brain-computer interface movement task using a non-invasive, high-resolution electrotactile vision substitution system. We compared the accuracy and movement times during a center-out cursor movement task, and found that the task performance with tactile feedback was comparable to visual feedback for 11 participants. These subjects were able to modulate the chosen BCI EEG features during both feedback modalities, indicating that the type of feedback chosen does not matter provided that the task information is clearly conveyed through the chosen medium. In addition, we tested a blind subject with the tactile feedback system, and found that the training time, accuracy, and movement times were indistinguishable from results obtained from subjects using visual feedback. We believe that BCI systems with alternative feedback pathways should be explored, allowing individuals with severe motor disabilities and accompanying reduced visual and sensory capabilities to effectively use a BCI.

MeSH terms

  • Brain-Computer Interfaces*
  • Feedback, Sensory / physiology*
  • Humans
  • Microelectrodes
  • Neural Pathways / physiology
  • Psychomotor Performance / physiology*
  • Reaction Time / physiology
  • Tongue / physiology*
  • Touch / physiology*