Nephrogenic systemic fibrosis and gadolinium-based contrast media: updated ESUR Contrast Medium Safety Committee guidelines
- PMID: 22865271
- DOI: 10.1007/s00330-012-2597-9
Nephrogenic systemic fibrosis and gadolinium-based contrast media: updated ESUR Contrast Medium Safety Committee guidelines
Abstract
Purpose: To update the guidelines of the Contrast Media Safety Committee (CMSC) of the European Society of Urogenital Radiology (ESUR) on nephrogenic systemic fibrosis and gadolinium-based contrast media.
Areas covered: Topics reviewed include the history, clinical features and prevalence of nephrogenic systemic fibrosis and the current understanding of its pathophysiology. The risk factors for NSF are discussed and prophylactic measures are recommended. The stability of the different gadolinium-based contrast media and the potential long-term effects of gadolinium in the body have also been reviewed.
Similar articles
-
Nephrogenic systemic fibrosis: UK survey of the use of gadolinium-based contrast media.Clin Radiol. 2010 Aug;65(8):636-41. doi: 10.1016/j.crad.2010.04.012. Epub 2010 Jun 11. Clin Radiol. 2010. PMID: 20599066
-
[Causal relationship between the use of gadolinium based contrast media and nephrogenic systemic fibrosis].Rev Med Chil. 2014 Dec;142(12):1565-74. doi: 10.4067/S0034-98872014001200010. Rev Med Chil. 2014. PMID: 25693439 Review. Spanish.
-
How to avoid nephrogenic systemic fibrosis: current guidelines in Europe and the United States.Radiol Clin North Am. 2009 Sep;47(5):871-5, vii. doi: 10.1016/j.rcl.2009.05.002. Radiol Clin North Am. 2009. PMID: 19744601 Review.
-
Nephrogenic systemic fibrosis: a systemic fibrosing disease resulting from gadolinium exposure.Best Pract Res Clin Rheumatol. 2012 Aug;26(4):489-503. doi: 10.1016/j.berh.2012.07.008. Best Pract Res Clin Rheumatol. 2012. PMID: 23040363 Review.
-
Safety of magnetic resonance contrast media: a review with special focus on nephrogenic systemic fibrosis.Top Magn Reson Imaging. 2015 Feb;24(1):57-65. doi: 10.1097/RMR.0b013e3182a14e79. Top Magn Reson Imaging. 2015. PMID: 25654421 Review. No abstract available.
Cited by
-
Cationic fluorinated micelles for cell labeling and 19F-MR imaging.Sci Rep. 2024 Sep 30;14(1):22613. doi: 10.1038/s41598-024-73511-8. Sci Rep. 2024. PMID: 39349687 Free PMC article.
-
The use of intravascular contrast media in patients with impaired kidney function - joint clinical practice position statement of the Polish Society of Nephrology and the Polish Medical Society of Radiology.Pol J Radiol. 2024 Mar 21;89:e161-e171. doi: 10.5114/pjr.2024.136950. eCollection 2024. Pol J Radiol. 2024. PMID: 38550960 Free PMC article. Review.
-
Rational Design of Magnetic Nanoparticles as T1-T2 Dual-Mode MRI Contrast Agents.Molecules. 2024 Mar 18;29(6):1352. doi: 10.3390/molecules29061352. Molecules. 2024. PMID: 38542988 Free PMC article. Review.
-
Lightweight preprocessing and template matching facilitate streamlined ischemic myocardial scar classification.J Med Imaging (Bellingham). 2024 Mar;11(2):024503. doi: 10.1117/1.JMI.11.2.024503. Epub 2024 Mar 21. J Med Imaging (Bellingham). 2024. PMID: 38525295
-
Accuracy of Noncontrast T2 SPACE in Active MS Cord Lesion Detection.AJNR Am J Neuroradiol. 2023 Dec 11;44(12):1458-1463. doi: 10.3174/ajnr.A8060. AJNR Am J Neuroradiol. 2023. PMID: 38049982
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources