One-hour rule-out and rule-in of acute myocardial infarction using high-sensitivity cardiac troponin T
- PMID: 22892889
- DOI: 10.1001/archinternmed.2012.3698
One-hour rule-out and rule-in of acute myocardial infarction using high-sensitivity cardiac troponin T
Abstract
Background: High-sensitivity cardiac troponin (hs-cTn) assays seem to improve the early diagnosis of acute myocardial infarction (AMI), but it is unknown how to best use them in clinical practice. Our objective was to develop and validate an algorithm for rapid rule-out and rule-in of AMI.
Methods: A prospective multicenter study enrolling 872 unselected patients with acute chest pain presenting to the emergency department. High-sensitivity cardiac troponin T (hs-cTnT) was measured in a blinded fashion at presentation and after 1 hour. The final diagnosis was adjudicated by 2 independent cardiologists. An hs-cTnT algorithm incorporating baseline values as well as absolute changes within the first hour was derived from 436 randomly selected patients and validated in the remaining 436 patients. The primary prognostic end point was death during 30 days of follow-up.
Results: Acute myocardial infarction was the final diagnosis in 17% of patients. After applying the hs-cTnT algorithm developed in the derivation cohort to the validation cohort, 259 patients (60%) could be classified as "rule-out," 76 patients (17%) as "rule-in," and 101 patients (23%) as in the "observational zone" within 1 hour. Overall, this resulted in a sensitivity and negative predictive value of 100% for rule-out, a specificity and positive predictive value of 97% and 84%, respectively, for rule-in, and a prevalence of AMI of 8% in the observational zone group. Cumulative 30-day survival was 99.8%, 98.6%, and 95.3% (P < .001) in patients classified as rule-out, observational zone, and rule-in, respectively.
Conclusions: Using a simple algorithm incorporating hs-cTnT baseline values and absolute changes within the first hour allowed a safe rule-out as well as an accurate rule-in of AMI within 1 hour in 77% of unselected patients with acute chest pain. This novel strategy may obviate the need for prolonged monitoring and serial blood sampling in 3 of 4 patients.
Comment in
-
Myocardial infarction rule-out in the emergency department: are high-sensitivity troponins the answer?: comment on "One-hour rule-out and rule-in of acute myocardial infarction using high-sensitivity cardiac troponin T".Arch Intern Med. 2012 Sep 10;172(16):1218-9. doi: 10.1001/archinternmed.2012.1808. Arch Intern Med. 2012. PMID: 22892634 No abstract available.
-
High-five for high-sensitivity cardiac troponin T: depends on the precision and analytical platform.JAMA Intern Med. 2013 Mar 25;173(6):477. doi: 10.1001/jamainternmed.2013.2270. JAMA Intern Med. 2013. PMID: 23529556 No abstract available.
-
Testing times: we are still some way from getting the best out of sensitive troponin assays.JAMA Intern Med. 2013 Mar 25;173(6):477-8. doi: 10.1001/jamainternmed.2013.2273. JAMA Intern Med. 2013. PMID: 23529557 No abstract available.
-
Testing times: we are still some way from getting the best out of sensitive troponin assays--reply.JAMA Intern Med. 2013 Mar 25;173(6):478. doi: 10.1001/jamainternmed.2013.2787. JAMA Intern Med. 2013. PMID: 23529558 No abstract available.
Similar articles
-
Two-hour algorithm for triage toward rule-out and rule-in of acute myocardial infarction using high-sensitivity cardiac troponin T.Am J Med. 2015 Apr;128(4):369-79.e4. doi: 10.1016/j.amjmed.2014.10.032. Epub 2014 Nov 13. Am J Med. 2015. PMID: 25446294
-
High-sensitivity cardiac troponin in the distinction of acute myocardial infarction from acute cardiac noncoronary artery disease.Circulation. 2012 Jul 3;126(1):31-40. doi: 10.1161/CIRCULATIONAHA.112.100867. Epub 2012 May 23. Circulation. 2012. PMID: 22623715 Clinical Trial.
-
Rapid rule out of acute myocardial infarction using undetectable levels of high-sensitivity cardiac troponin.Int J Cardiol. 2013 Oct 9;168(4):3896-901. doi: 10.1016/j.ijcard.2013.06.049. Epub 2013 Jul 20. Int J Cardiol. 2013. PMID: 23876467
-
Early Rule-Out Strategies in the Emergency Department Utilizing High-Sensitivity Cardiac Troponin Assays.Clin Chem. 2021 Jan 8;67(1):114-123. doi: 10.1093/clinchem/hvaa226. Clin Chem. 2021. PMID: 33279982 Review.
-
High-sensitivity troponin assays for the early rule-out or diagnosis of acute myocardial infarction in people with acute chest pain: a systematic review and cost-effectiveness analysis.Health Technol Assess. 2015 Jun;19(44):1-234. doi: 10.3310/hta19440. Health Technol Assess. 2015. PMID: 26118801 Free PMC article. Review.
Cited by
-
A multicenter prospective study on the ESC algorithm for the early diagnosis of non-ST-elevation myocardial infarction.iScience. 2024 Aug 5;27(9):110643. doi: 10.1016/j.isci.2024.110643. eCollection 2024 Sep 20. iScience. 2024. PMID: 39262795 Free PMC article.
-
How to Approach Patients with Acute Chest Pain.Rev Cardiovasc Med. 2024 Aug 22;25(8):302. doi: 10.31083/j.rcm2508302. eCollection 2024 Aug. Rev Cardiovasc Med. 2024. PMID: 39228492 Free PMC article. Review.
-
Risk scores and coronary artery disease in patients with suspected acute coronary syndrome and intermediate cardiac troponin concentrations.Open Heart. 2024 Aug 3;11(2):e002755. doi: 10.1136/openhrt-2024-002755. Open Heart. 2024. PMID: 39097328 Free PMC article.
-
Evaluating the Rates of Mortality and Cardiac Catheterization Using High-Sensitivity Troponin and Conventional Troponin Assays.Cureus. 2024 Jun 30;16(6):e63538. doi: 10.7759/cureus.63538. eCollection 2024 Jun. Cureus. 2024. PMID: 39086787 Free PMC article.
-
Adoption of high-sensitivity cardiac troponin for risk stratification of patients with suspected myocardial infarction: a multicentre cohort study.Lancet Reg Health Eur. 2024 Jun 13;43:100960. doi: 10.1016/j.lanepe.2024.100960. eCollection 2024 Aug. Lancet Reg Health Eur. 2024. PMID: 38975590 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials