The Zitelli design for bilobed flap applied on skin defects after digital mucous cyst excision. A review of 9 cases

Tech Hand Up Extrem Surg. 2012 Sep;16(3):124-6. doi: 10.1097/BTH.0b013e3182560336.

Abstract

Mucous cysts do not always require treatment. Nevertheless, patients often ask for excision because of pain or esthetics. Flap coverage is usually a concomitant procedure, which improves the quality of the skin overlying the distal interphalangeal joint. We propose the Zimany bilobed flap in this indication, and particularly its newer geometric design developed by Zitelli. We report the use of this flap in 9 cysts. Wound healing was fast with a good outcome. This flap design is an easy, safe procedure, and the Zitelli geometric design is a clear improvement for the reproducibility and learning curve.

Publication types

  • Evaluation Study

MeSH terms

  • Cysts / pathology
  • Cysts / surgery*
  • Esthetics
  • Female
  • Fingers
  • Graft Survival
  • Humans
  • Male
  • Mucous Membrane / pathology
  • Mucous Membrane / surgery
  • Sampling Studies
  • Skin Diseases / pathology
  • Skin Diseases / surgery*
  • Surgical Flaps / blood supply*
  • Wound Healing / physiology*