In vivo degradation performance of micro-arc-oxidized magnesium implants: a micro-CT study in rats
- PMID: 23022544
- DOI: 10.1016/j.actbio.2012.09.017
In vivo degradation performance of micro-arc-oxidized magnesium implants: a micro-CT study in rats
Abstract
Biodegradable Mg alloys are of great interest for osteosynthetic applications because they do not require surgical removal after they have served their purpose. In this study, fast-degrading ZX50 Mg-based implants were surface-treated by micro-arc oxidation (MAO), to alter the initial degradation, and implanted along with untreated ZX50 controls in the femoral legs of 20 male Sprague-Dawley rats. Their degradation was monitored by microfocus computed tomography (μCT) over a total observation period of 24weeks, and histological analysis was performed after 4, 12 and 24weeks. While the MAO-treated samples showed almost no corrosion in the first week, they revealed an accelerated degradation rate after the third week, even faster than that of the untreated ZX50 implants. This increase in degradation rate can be explained by an increase in the surface-area-to-volume ratio of MAO-treated implants, which degrade inhomogeneously via localized corrosion attacks. The histological analyses show that the initially improved corrosion resistance of the MAO implants has a positive effect on bone and tissue response: The reduced hydrogen evolution (due to reduced corrosion) makes possible increased osteoblast apposition from the very beginning, thus generating a stable bone-implant interface. As such, MAO treatment appears to be very interesting for osteosynthetic implant applications, as it delays implant degradation immediately after implantation, enhances fracture stabilization, minimizes the burden on the postoperatively irritated surrounding tissue and generates good bone-implant connections, followed by accelerated degradation in the later stage of bone healing.
Copyright © 2012 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Similar articles
-
Magnesium alloys for temporary implants in osteosynthesis: in vivo studies of their degradation and interaction with bone.Acta Biomater. 2012 Mar;8(3):1230-8. doi: 10.1016/j.actbio.2011.11.008. Epub 2011 Nov 11. Acta Biomater. 2012. PMID: 22107870
-
[In vivo experimental study on MAO-ZK60 magnesium alloy bio-safety and degradation].Zhongguo Gu Shang. 2013 May;26(5):423-8. Zhongguo Gu Shang. 2013. PMID: 23937039 Chinese.
-
Long-term in vivo degradation behavior and near-implant distribution of resorbed elements for magnesium alloys WZ21 and ZX50.Acta Biomater. 2016 Sep 15;42:440-450. doi: 10.1016/j.actbio.2016.06.025. Epub 2016 Jun 22. Acta Biomater. 2016. PMID: 27343708
-
[Progress of in vivo study on degradable magnesium alloys application as bone-implant materials].Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2012 Nov;26(11):1381-6. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2012. PMID: 23230677 Review. Chinese.
-
Indwelling Neural Implants: Strategies for Contending with the In Vivo Environment.Boca Raton (FL): CRC Press/Taylor & Francis; 2008. Boca Raton (FL): CRC Press/Taylor & Francis; 2008. PMID: 21204399 Free Books & Documents. Review.
Cited by
-
Mg-Zn-Ca Alloy (ZX00) Screws Are Resorbed at a Mean of 2.5 Years After Medial Malleolar Fracture Fixation: Follow-up of a First-in-humans Application and Insights From a Sheep Model.Clin Orthop Relat Res. 2023 Aug 21;482(1):184-97. doi: 10.1097/CORR.0000000000002799. Online ahead of print. Clin Orthop Relat Res. 2023. PMID: 37603369
-
In vitro and in vivo study on fine-grained Mg-Zn-RE-Zr alloy as a biodegradeable orthopedic implant produced by friction stir processing.Bioact Mater. 2023 Jun 24;28:448-466. doi: 10.1016/j.bioactmat.2023.06.010. eCollection 2023 Oct. Bioact Mater. 2023. PMID: 37408797 Free PMC article.
-
Effects of Altering Magnesium Metal Surfaces on Degradation In Vitro and In Vivo during Peripheral Nerve Regeneration.Materials (Basel). 2023 Jan 30;16(3):1195. doi: 10.3390/ma16031195. Materials (Basel). 2023. PMID: 36770202 Free PMC article.
-
A SiO2 layer on PEO-treated Mg for enhanced corrosion resistance and bone regeneration.Front Bioeng Biotechnol. 2022 Dec 23;10:1053944. doi: 10.3389/fbioe.2022.1053944. eCollection 2022. Front Bioeng Biotechnol. 2022. PMID: 36619395 Free PMC article.
-
Biocompatibility evaluation of peo-treated magnesium alloy implants placed in rabbit femur condyle notches and paravertebral muscles.Biomater Res. 2022 Jul 6;26(1):29. doi: 10.1186/s40824-022-00279-1. Biomater Res. 2022. PMID: 35794655 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials