Highly cross-linked polyethylene in posterior stabilized total knee arthroplasty: early results

Orthop Clin North Am. 2012 Nov;43(5):e35-8. doi: 10.1016/j.ocl.2012.07.005. Epub 2012 Sep 27.

Abstract

This article examines whether any new complications were associated with highly cross-linked polyethylene in posterior stabilized total knee arthroplasty (TKA) due to its altered mechanical properties. Average preoperative Knee Society Scores (KSS) were 49.7 and 51.5, with a range of movement (ROM) of 3° to 116°, and average postoperative KSS were 87.7 clinical and 89.7, with ROM of 0° to 123°. Postoperative alignment averaged 3.8° of valgus. There were no cases of polyethylene or post failure. Short-term results of posterior stabilized TKAs using highly cross-linked polyethylene show good functional outcomes with no evidence of loosening or tibial post failure.

MeSH terms

  • Acrylic Resins / therapeutic use*
  • Adult
  • Aged
  • Aged, 80 and over
  • Arthroplasty, Replacement, Knee*
  • Female
  • Humans
  • Male
  • Materials Testing
  • Middle Aged
  • Prosthesis Failure
  • Treatment Outcome

Substances

  • Acrylic Resins
  • GUR 1050 resin