Diagnostic performance of dark-blood T2-weighted CMR for evaluation of acute myocardial injury
- PMID: 23192160
- DOI: 10.1097/RLI.0b013e3182718672
Diagnostic performance of dark-blood T2-weighted CMR for evaluation of acute myocardial injury
Abstract
Objectives: We compared the image quality and diagnostic performance of 2 fat-suppression methods for black-blood T2-weighted fast spin-echo (FSE), which are as follows: (a) short T1 inversion recovery (STIR; FSE-STIR) and (b) spectral adiabatic inversion recovery (SPAIR; FSE-SPAIR), for detection of acute myocardial injury.
Background: Edema-sensitive T2-weighted FSE cardiac magnetic resonance (CMR) imaging is useful in detecting acute myocardial injury but may experience reduced myocardial signal and signal dropout. The SPAIR pulse aims to eliminate artifacts associated with the STIR pulse.
Materials and methods: A total of 65 consecutive patients referred for CMR evaluation of myocardial structure and function underwent FSE-STIR and FSE-SPAIR, in addition to cine and late gadolinium enhancement (LGE) CMR. T2-weighted FSE images were independently evaluated by 2 readers for image quality and artifacts (Likert scale of 1-5; best-worst) and presence of increased myocardial signal suggestive of edema. In addition, clinical CMR interpretation, incorporating all CMR sequences available, was recorded for comparison. Diagnostic performance of each T2-weighted sequence was measured using recent (<30 days) troponin elevation greater than 2 times the upper limit of normal as the reference standard for acute myocardial injury.
Results: Of the 65 patients, there were 21 (32%) with acute myocardial injury. Image quality and artifact scores were significantly better with FSE-SPAIR compared with FSE-STIR (2.15 vs 2.68, P < 0.01; 2.62 vs 3.05, P < 0.01, respectively). The sensitivity, specificity, positive predictive value, and negative predictive value for acute myocardial injury were as follows: 29%, 93%, 67%, and 73% for FSE-SPAIR; 38%, 91%, 67%, and 75% for FSE-STIR; 71%, 98%, 94%, and 88% for clinical interpretation including LGE, T2, and wall motion. There was a statistically significant difference in sensitivity between the clinical interpretation and each of the T2-weighted sequences but not between each T2-weighted sequence.
Conclusions: Although FSE-SPAIR demonstrated significantly improved image quality and decreased artifacts, isolated interpretations of each T2-weighted technique demonstrated high specificity but overall low sensitivity for the detection of myocardial injury, with no difference in accuracy between the techniques. However, real-world interpretation in combination with cine and LGE CMR methods significantly improves the overall sensitivity and diagnostic performance.
Similar articles
-
MR diagnosis of bone contusions of the knee: comparison of coronal T2-weighted fast spin-echo with fat saturation and fast spin-echo STIR images with conventional STIR images.AJR Am J Roentgenol. 1996 Jan;166(1):119-24. doi: 10.2214/ajr.166.1.8571859. AJR Am J Roentgenol. 1996. PMID: 8571859
-
A new approach towards improved visualization of myocardial edema using T2-weighted imaging: a cardiovascular magnetic resonance (CMR) study.J Magn Reson Imaging. 2011 Aug;34(2):286-92. doi: 10.1002/jmri.22622. J Magn Reson Imaging. 2011. PMID: 21780224
-
Diagnostic performance of cardiovascular magnetic resonance in patients with suspected acute myocarditis: comparison of different approaches.J Am Coll Cardiol. 2005 Jun 7;45(11):1815-22. doi: 10.1016/j.jacc.2004.11.069. J Am Coll Cardiol. 2005. PMID: 15936612
-
Cardiovascular magnetic resonance in patients with magnetic resonance conditional pacemaker systems at 1.5 T: influence of pacemaker related artifacts on image quality including first pass perfusion, aortic and mitral valve assessment, flow measurement, short tau inversion recovery and T1-weighted imaging.Int J Cardiovasc Imaging. 2017 Mar;33(3):383-394. doi: 10.1007/s10554-016-1012-z. Epub 2016 Nov 4. Int J Cardiovasc Imaging. 2017. PMID: 27815793 Review.
-
Recent Advances in T1 and T2 Mapping in the Assessment of Fulminant Myocarditis by Cardiac Magnetic Resonance.Curr Cardiol Rep. 2020 May 29;22(7):47. doi: 10.1007/s11886-020-01295-0. Curr Cardiol Rep. 2020. PMID: 32472218 Review.
Cited by
-
Multimodality Imaging of Sudden Cardiac Death and Acute Complications in Acute Coronary Syndrome.J Clin Med. 2022 Sep 26;11(19):5663. doi: 10.3390/jcm11195663. J Clin Med. 2022. PMID: 36233531 Free PMC article. Review.
-
Cardiac MRI Assessment of Nonischemic Myocardial Inflammation: State of the Art Review and Update on Myocarditis Associated with COVID-19 Vaccination.Radiol Cardiothorac Imaging. 2021 Nov 18;3(6):e210252. doi: 10.1148/ryct.210252. eCollection 2021 Dec. Radiol Cardiothorac Imaging. 2021. PMID: 34934954 Free PMC article. Review.
-
Cardiac T2 mapping: robustness and homogeneity of standardized in-line analysis.J Cardiovasc Magn Reson. 2020 May 28;22(1):39. doi: 10.1186/s12968-020-00619-x. J Cardiovasc Magn Reson. 2020. PMID: 32460852 Free PMC article.
-
Clinical Importance of Myocardial T2 Mapping and Texture Analysis.Magn Reson Med Sci. 2021 Jun 1;20(2):139-151. doi: 10.2463/mrms.rev.2020-0007. Epub 2020 May 11. Magn Reson Med Sci. 2021. PMID: 32389929 Free PMC article. Review.
-
Cardiovascular magnetic resonance imaging assessment of outcomes in acute myocardial infarction.World J Cardiol. 2017 Feb 26;9(2):109-133. doi: 10.4330/wjc.v9.i2.109. World J Cardiol. 2017. PMID: 28289525 Free PMC article. Review.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical