Long-term results of aortic root repair using the reimplantation technique
- PMID: 23260437
- DOI: 10.1016/j.jtcvs.2012.11.075
Long-term results of aortic root repair using the reimplantation technique
Abstract
Objectives: Aortic valve sparing is frequently performed to treat patients with aortic root aneurysm, but there is an inadequate amount of information regarding its long-term durability. This study examines the long-term results of reimplantation of the aortic valve in patients with aortic root aneurysms.
Methods: From August 1989 to December 2010, 296 consecutive patients had reimplantation of the aortic valve into a tubular Dacron graft. Their mean age was 45 years (range, 11-79 years), and 78% were men. Of the patients, 36% had Marfan syndrome and 11% had bicuspid aortic valve. Patients were followed prospectively with periodic images of the aortic root and remaining aorta. The mean follow-up was 6.9 ± 4.5 years. There were 21 patients at risk at 15 years.
Results: There were 4 operative and 18 late deaths. The survival at 5, 10, and 15 years was 95.1% ± 3.5%, 93.1% ± 4.4%, and 76.5% ± 18%, respectively. Only 3 patients required reoperation on the aortic valve; all 3 patients had the Bentall procedure. Freedom from reoperation at 5, 10, and 15 years was 99.7% ± 2.0%, 97.8% ± 5.3%, and 97.8% ± 5.3%, respectively. During follow-up, moderate aortic insufficiency developed in 9 patients, and severe aortic insufficiency developed in 2 patients. Freedom from moderate or severe aortic insufficiency at 5, 10, and 15 years was 98.3% ± 3.5%, 92.9% ± 6.5%, and 89.4% ± 12%, respectively.
Conclusions: The function of the aortic valve implanted inside a tubular Dacron graft remains normal at 15 years in most patients after this type of aortic valve-sparing operation.
Copyright © 2013 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Similar articles
-
Reimplantation valve-sparing aortic root replacement with the Valsalva graft: what have we learnt after 100 cases?Interact Cardiovasc Thorac Surg. 2009 Jul;9(1):113-6. doi: 10.1510/icvts.2009.202622. Epub 2009 Apr 28. Interact Cardiovasc Thorac Surg. 2009. PMID: 19401293
-
Use of the Valsalva graft and long-term follow-up.J Thorac Cardiovasc Surg. 2010 Dec;140(6 Suppl):S23-7; discussion S45-51. doi: 10.1016/j.jtcvs.2010.07.060. J Thorac Cardiovasc Surg. 2010. PMID: 21092792
-
A quarter of a century of experience with aortic valve-sparing operations.J Thorac Cardiovasc Surg. 2014 Sep;148(3):872-9; discussion 879-80. doi: 10.1016/j.jtcvs.2014.04.048. Epub 2014 May 15. J Thorac Cardiovasc Surg. 2014. PMID: 24930611
-
Current readings: Aortic valve-sparing operations.Semin Thorac Cardiovasc Surg. 2014 Autumn;26(3):231-8. doi: 10.1053/j.semtcvs.2014.10.002. Epub 2014 Nov 11. Semin Thorac Cardiovasc Surg. 2014. PMID: 25527017 Review.
-
Is aortic valve-sparing operation or replacement with a composite graft the best option for aortic root and ascending aortic aneurysm?Interact Cardiovasc Thorac Surg. 2009 Jan;8(1):134-47. doi: 10.1510/icvts.2008.186544. Epub 2008 Oct 21. Interact Cardiovasc Thorac Surg. 2009. PMID: 18940830 Review.
Cited by
-
A 3D-Printed Externally Adjustable Symmetrically Extensible (EASE) Aortic Annuloplasty Ring for Root Repair and Aortic Valve Regurgitation.Cardiovasc Eng Technol. 2024 Jan 18. doi: 10.1007/s13239-024-00709-2. Online ahead of print. Cardiovasc Eng Technol. 2024. PMID: 38238600
-
Mid-term outcomes of total neointima implantation in surgical repair of acute type A aortic dissection.J Clin Hypertens (Greenwich). 2024 Feb;26(2):155-165. doi: 10.1111/jch.14762. Epub 2024 Jan 12. J Clin Hypertens (Greenwich). 2024. PMID: 38214206 Free PMC article.
-
Survival and repair durability in patients undergoing concomitant aortic valve reimplantation and mitral valve repair.JTCVS Tech. 2023 Sep 22;22:159-168. doi: 10.1016/j.xjtc.2023.09.015. eCollection 2023 Dec. JTCVS Tech. 2023. PMID: 38152191 Free PMC article.
-
Twenty-five year experience with aortic valve-sparing root replacement in a single teaching center.Front Cardiovasc Med. 2023 Mar 10;10:1104149. doi: 10.3389/fcvm.2023.1104149. eCollection 2023. Front Cardiovasc Med. 2023. PMID: 36970369 Free PMC article.
-
Biomechanical evaluation of aortic regurgitation from cusp prolapse using an ex vivo 3D-printed commissure geometric alignment device.J Cardiothorac Surg. 2022 Dec 10;17(1):303. doi: 10.1186/s13019-022-02049-5. J Cardiothorac Surg. 2022. PMID: 36496476 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical