Semi-automatic catheter reconstruction from two views
- PMID: 23286096
- DOI: 10.1007/978-3-642-33418-4_72
Semi-automatic catheter reconstruction from two views
Abstract
We propose novel methods for (a) detection of a catheter in fluoroscopic images and (b) reconstruction of this catheter from two views. The novelty of (a) is a reduced user interaction and a higher accuracy. It requires only a single seed point on the catheter in the fluoroscopic image. Using this starting point, possible parts of the catheter are detected using a graph search. An evaluation of the detection using 66 clinical fluoroscopic images yielded an average error of 0.7 mm +/- 2.0 mm. The novelty of (b) is a better ability to deal with highly curved objects as it selects an optimal set of point correspondences from two point sequences describing the catheters in two fluoroscopic images. The selected correspondences are then used for computation of the 3-D reconstruction. The evaluation on 33 clinical biplane images yielded an average backprojection error of 0.4 mm +/- 0.6 mm.
Similar articles
-
Respiratory motion compensation by model-based catheter tracking during EP procedures.Med Image Anal. 2010 Oct;14(5):695-706. doi: 10.1016/j.media.2010.05.006. Epub 2010 Jun 10. Med Image Anal. 2010. PMID: 20579931
-
3-D respiratory motion compensation during EP procedures by image-based 3-D lasso catheter model generation and tracking.Med Image Comput Comput Assist Interv. 2009;12(Pt 1):394-401. doi: 10.1007/978-3-642-04268-3_49. Med Image Comput Comput Assist Interv. 2009. PMID: 20426012
-
Fully automatic catheter localization in C-arm images using ł1-sparse coding.Med Image Comput Comput Assist Interv. 2014;17(Pt 2):570-7. doi: 10.1007/978-3-319-10470-6_71. Med Image Comput Comput Assist Interv. 2014. PMID: 25485425
-
Navigation systems for ablation.J Vasc Interv Radiol. 2010 Aug;21(8 Suppl):S257-63. doi: 10.1016/j.jvir.2010.05.003. J Vasc Interv Radiol. 2010. PMID: 20656236 Free PMC article. Review.
-
Radiofrequency ablation: the percutaneous approach.Recent Results Cancer Res. 2006;167:39-52. doi: 10.1007/3-540-28137-1_3. Recent Results Cancer Res. 2006. PMID: 17044295 Review. No abstract available.
Cited by
-
Evaluation and Verification of Fast Computational Simulations of Stent-Graft Deployment in Endovascular Aneurysmal Repair.Front Med Technol. 2021 Jul 20;3:704806. doi: 10.3389/fmedt.2021.704806. eCollection 2021. Front Med Technol. 2021. PMID: 35047943 Free PMC article.
-
Shape Reconstruction Processes for Interventional Application Devices: State of the Art, Progress, and Future Directions.Front Robot AI. 2021 Nov 19;8:758411. doi: 10.3389/frobt.2021.758411. eCollection 2021. Front Robot AI. 2021. PMID: 34869615 Free PMC article. Review.
-
Simultaneous reconstruction of multiple stiff wires from a single X-ray projection for endovascular aortic repair.Int J Comput Assist Radiol Surg. 2019 Nov;14(11):1891-1899. doi: 10.1007/s11548-019-02052-7. Epub 2019 Aug 22. Int J Comput Assist Radiol Surg. 2019. PMID: 31440962
-
4D interventional device reconstruction from biplane fluoroscopy.Med Phys. 2016 Mar;43(3):1324-34. doi: 10.1118/1.4941950. Med Phys. 2016. PMID: 26936717 Free PMC article.
-
Automatic 3D reconstruction of electrophysiology catheters from two-view monoplane C-arm image sequences.Int J Comput Assist Radiol Surg. 2016 Jul;11(7):1319-28. doi: 10.1007/s11548-015-1325-8. Epub 2015 Nov 28. Int J Comput Assist Radiol Surg. 2016. PMID: 26615429
Publication types
MeSH terms
LinkOut - more resources
Other Literature Sources
Medical