Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 Apr;189(4):315-20.
doi: 10.1007/s00066-012-0271-4. Epub 2013 Feb 28.

Set-up uncertainty during breast radiotherapy. Image-guided radiotherapy for patients with initial extensive variation

Affiliations

Set-up uncertainty during breast radiotherapy. Image-guided radiotherapy for patients with initial extensive variation

D S Yang et al. Strahlenther Onkol. 2013 Apr.

Abstract

Purpose: The aim of this work was to establish a customized strategy for image-guided radiotherapy during whole breast irradiation. Risk factors associated with extensive errors were assessed.

Methods and materials: A series of 176 consecutive breasts in 174 patients were retrospectively assessed. Electronic portal images from 914 medial and 807 lateral directions were reviewed. On the basis of the chest wall, the deviations between the simulation and each treatment were measured. The systematic (Σ) and random error (σ) of population, and the planning target volume (PTV) margin (2 Σ + 0.7σ) were calculated for each direction. Extensive set-up errors were defined as the fraction over the PTV margins in any direction. For extensive set-up errors, χ(2) tests and logistic regression analyses were conducted.

Results: The medial and lateral PTV margins for the right-left, superior-inferior, and anterior-posterior axes and the rotation of collimator were 2.6 and 2.4 mm, 4.6 and 4.6 mm, and 3.1 and 3.3 mm and 2.8 and 2.9 ° and cut-off values for extensive errors were 3, 5, and 4 mm and 3 °, respectively. In χ(2) tests, tumor in upper outer quadrant (p = 0.012) and chest wall thickness ≥ 2.0 cm (p = 0.003) for medial portals and age group (p = 0.036) for lateral portals were associated with extensive errors. In multivariate tests, the extensive error on the initial fraction had a high probability of extensive set-up errors in both medial (OR = 4.26, p < 0.001) and lateral portals (OR = 3.07, p < 0.001).

Conclusion: In terms of the set-up uncertainty during breast irradiation, patients with extensive error in the initial treatment should be closely observed with serial image-guided radiotherapy.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Breast Cancer. 2014 Mar;21(2):162-9 - PubMed
    1. Radiat Oncol. 2010 Oct 26;5:96 - PubMed
    1. Cancer Radiother. 2005 Nov;9(6-7):414-21 - PubMed
    1. Semin Radiat Oncol. 2012 Jan;22(1):50-61 - PubMed
    1. Radiother Oncol. 2007 Mar;82(3):254-64 - PubMed

MeSH terms

LinkOut - more resources