Determination of disk diffusion and MIC quality control guidelines for GSK2251052: a novel boron-containing antibacterial

Diagn Microbiol Infect Dis. 2013 Apr;75(4):437-9. doi: 10.1016/j.diagmicrobio.2013.01.007. Epub 2013 Feb 23.

Abstract

GSK2251052 is a boron-containing antimicrobial agent in clinical development for the treatment of serious Gram-negative bacterial infections. These GSK2251052 quality control (QC) studies were performed to establish ranges for control strains (broth microdilution [BMD] MIC and disk diffusion zones) as follows: Pseudomonas aeruginosa ATCC 27853 (2-8 μg/mL and 15-24 mm), Escherichia coli ATCC 25922 (0.5-2 μg/mL and 23-30 mm), Haemophilus influenzae ATCC 49247 (0.25-1 μg/mL and 22-31 mm), Streptococcus pneumoniae ATCC 49619 (0.25-1 μg/mL and 19-28 mm), Bacteroides fragilis ATCC 25285 (1-4 μg/mL [BMD] and 1-4 μg/mL [agar dilution]), and Bacteroides thetaiotaomicron ATCC 29741 (1-8 μg/mL [BMD] and 2-8 μg/mL [agar dilution]). These ranges, approved by Clinical and Laboratory Standards Institute, will be crucial in accurately evaluating GSK2251052 in vitro potency.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Anti-Bacterial Agents / pharmacology*
  • Gram-Negative Bacteria / drug effects*
  • Gram-Positive Bacteria / drug effects*
  • Humans
  • Microbial Sensitivity Tests / methods
  • Microbial Sensitivity Tests / standards*
  • Quality Control*

Substances

  • Anti-Bacterial Agents