Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 Jun;20(e1):e52-8.
doi: 10.1136/amiajnl-2012-001328. Epub 2013 Apr 11.

A long-term follow-up evaluation of electronic health record prescribing safety

Affiliations

A long-term follow-up evaluation of electronic health record prescribing safety

Erika L Abramson et al. J Am Med Inform Assoc. 2013 Jun.

Abstract

Objective: To be eligible for incentives through the Electronic Health Record (EHR) Incentive Program, many providers using older or locally developed EHRs will be transitioning to new, commercial EHRs. We previously evaluated prescribing errors made by providers in the first year following transition from a locally developed EHR with minimal prescribing clinical decision support (CDS) to a commercial EHR with robust CDS. Following system refinements, we conducted this study to assess the rates and types of errors 2 years after transition and determine the evolution of errors.

Materials and methods: We conducted a mixed methods cross-sectional case study of 16 physicians at an academic-affiliated ambulatory clinic from April to June 2010. We utilized standardized prescription and chart review to identify errors. Fourteen providers also participated in interviews.

Results: We analyzed 1905 prescriptions. The overall prescribing error rate was 3.8 per 100 prescriptions (95% CI 2.8 to 5.1). Error rates were significantly lower 2 years after transition (p<0.001 compared to pre-implementation, 12 weeks and 1 year after transition). Rates of near misses remained unchanged. Providers positively appreciated most system refinements, particularly reduced alert firing.

Discussion: Our study suggests that over time and with system refinements, use of a commercial EHR with advanced CDS can lead to low prescribing error rates, although more serious errors may require targeted interventions to eliminate them. Reducing alert firing frequency appears particularly important. Our results provide support for federal efforts promoting meaningful use of EHRs.

Conclusions: Ongoing error monitoring can allow CDS to be optimally tailored and help achieve maximal safety benefits.

Clinical trials registration: ClinicalTrials.gov, Identifier: NCT00603070.

Keywords: Transition, EHR, Ambulatory, Prescribing Safety.

PubMed Disclaimer

Similar articles

Cited by

References

    1. The Office of the National Coordinator for Health Information Technology. Electronic health records and meaningful use. Center for Medicare and Medicaid Services, 2010. http://healthit.hhs.gov/portal/server.pt?open=512&objID=2996&mode=2 (accessed 11 July 2012)
    1. Gandhi TK, Weingart SN, Seger AC, et al. Outpatient prescribing errors and the impact of computerized prescribing. J Gen Intern Med 2005;20:837–41 - PMC - PubMed
    1. Gandhi TK, Weingart SN, Borus J, et al. Adverse drug events in ambulatory care. N Engl J Med 2003;348:1556–64 - PubMed
    1. Abramson EL, Bates DW, Jenter C, et al. Ambulatory prescribing errors among community-based providers in two states. J Am Med Inform Assoc 2011;19:644–8 - PMC - PubMed
    1. Cherry DK, Hing E, Woodwell DA, et al. National Ambulatory Medical Care Survey: 2006 summary. Hyattsville, MD: Division of Health Care Statistics, US Department of Health & Human Services, Centers for Disease Control and Prevention, National Center for Health Statistics. Natl Health Stat Report, 2008:1–39 - PubMed

Publication types

MeSH terms

Substances

Associated data