Transcatheter aortic valve implantation in patients of small body size

Catheter Cardiovasc Interv. 2014 Aug 1;84(2):272-80. doi: 10.1002/ccd.24970. Epub 2014 May 3.

Abstract

Aims: The aim of this study was to evaluate the efficacy and safety of transcatheter aortic valve implantation (TAVI) in patients of small body size (SB).

Methods and results: Between October 2006 and November 2011, 424 patients undergoing TAVI were evaluated. Patients with a small body surface area (BSA; <1.75 m(2)) were defined as the "SB group" (n = 215) and the remaining large BSA patients as the "LB group" (n = 209). In the SB group, mean annulus diameter measured by CT and minimal femoral artery diameter were significantly smaller (23.1 ± 1.92 vs. 24.3 ± 1.91 mm, P < 0.01; 7.59 ± 1.06 vs. 8.29 ± 1.34 mm, P < 0.01, respectively). The logistic EuroSCORE was similar between groups (22.5 ± 10.4 vs. 23.4 ± 12.0; P = 0.43). Equivalent device success (91.2% vs. 91.4%; P = 0.94) and 30-day survival rates (85.1% vs. 87.6%; P = 0.46) were achieved in both groups. Vascular complications and the 30-day combined safety end point rate were significantly higher in the SB group (13.0% vs. 4.3%, P < 0.01; 27.4% vs. 18.3%, P = 0.03, respectively). Similar post-procedural mean pressure gradient was achieved in both groups (10.2 ± 4.3 vs. 11.0 ± 4.6 mmHg; P = 0.12). Multivariate analysis showed that BSA was one of the independent predictors of 30-day combined safety end point (Odds ratio: 0.20; 95% confidence interval (CI): 0.05-0.88; P = 0.03). However, Kaplan-Meier analysis revealed no significant difference in mid-term survival rate between groups (log-rank P = 0.64).

Conclusions: TAVI in SB patients resulted in similar clinical outcomes with effective post-procedural hemodynamics compared with LB patients. Care should be taken to avoid vascular complications in SB patients.

Keywords: aortic valve; small body size; transcatheter aortic valve implantation; vascular complication.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Valve Stenosis / diagnosis
  • Aortic Valve Stenosis / mortality
  • Aortic Valve Stenosis / physiopathology
  • Aortic Valve Stenosis / therapy*
  • Aortic Valve* / diagnostic imaging
  • Aortic Valve* / physiopathology
  • Body Mass Index
  • Body Size*
  • Body Surface Area
  • Cardiac Catheterization / adverse effects
  • Cardiac Catheterization / instrumentation
  • Cardiac Catheterization / methods*
  • Cardiac Catheterization / mortality
  • Femoral Artery / diagnostic imaging
  • Heart Valve Prosthesis
  • Heart Valve Prosthesis Implantation / adverse effects
  • Heart Valve Prosthesis Implantation / instrumentation
  • Heart Valve Prosthesis Implantation / methods*
  • Heart Valve Prosthesis Implantation / mortality
  • Hemodynamics
  • Humans
  • Kaplan-Meier Estimate
  • Logistic Models
  • Male
  • Multivariate Analysis
  • Odds Ratio
  • Prosthesis Design
  • Risk Factors
  • Severity of Illness Index
  • Time Factors
  • Tomography, X-Ray Computed
  • Treatment Outcome