Off-resonance insensitive complementary SPAtial Modulation of Magnetization (ORI-CSPAMM) for quantification of left ventricular twist

J Magn Reson Imaging. 2014 Feb;39(2):339-45. doi: 10.1002/jmri.24154. Epub 2013 Apr 26.

Abstract

Purpose: To evaluate Off Resonance Insensitive Complementary SPAtial Modulation of Magnetization (ORI-CSPAMM) and Fourier Analysis of STimulated echoes (FAST) for the quantification of left ventricular (LV) systolic and diastolic function and compare it with the previously validated FAST+SPAMM technique.

Materials and methods: LV short-axis tagged images were acquired with ORI-CSPAMM and SPAMM in healthy volunteers (n = 13). The FAST method was used to automatically estimate LV systolic and diastolic twist parameters from rotation of the stimulated echo and stimulated anti-echo about the middle of k-space subsequent to ∼3 min of user interaction.

Results: There was no significant difference between measures obtained for FAST+ORI-CSPAMM and FAST+SPAMM for mean peak twist (12.9 ± 3.4° versus 11.9 ± 4.0°; P = 0.4), torsion (3.3 ± 0.9°/cm versus 2.9 ± 1.0°/cm, P = 0.3), circumferential-longitudinal shear angle (9.1 ± 3.0° versus 8.2 ± 3.4°, P = 0.3), twisting rate (79.6 ± 20.2°/s versus 68.2 ± 23.4°/s, P = 0.1), untwisting rate (-117.5 ± 31.4°/s versus -106.6 ± 32.4°/s, P = 0.3), normalized untwisting rate (-9.3 ± 2.0/s versus -9.9 ± 4.4/s, P = 0.7), and time of peak twist (281 ± 18 ms versus 293 ± 25 ms, P = 0.04). FAST+ORI-CSPAMM also provided measures of duration of untwisting (148 ± 21 ms) and the ratio of rapid untwisting to peak twist (0.9 ± 0.3). Bland-Altman analysis of FAST+ORI-CSPAMM and FAST+SPAMM twist data demonstrates excellent agreement with a bias of -0.1° and 95% confidence intervals of (-1.0°, 3.2°).

Conclusion: FAST+ORI-CSPAMM is a semi-automated method that provides a quick and quantitative assessment of LV systolic and diastolic twist and torsion. ORI-CSPAMM corrects off-resonance accrued during tagging preparation and readout and visibly removes chemical shift from the tagging pattern, which confers greater robustness to the derived quantitative measures.

Keywords: diastole; left ventricle; off-resonance; tagging; twist.

Publication types

  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Algorithms
  • Cardiac-Gated Imaging Techniques / methods*
  • Diastole
  • Female
  • Heart Ventricles / anatomy & histology
  • Humans
  • Image Enhancement / methods
  • Image Interpretation, Computer-Assisted / methods*
  • Imaging, Three-Dimensional / methods*
  • Magnetic Resonance Imaging, Cine / methods*
  • Male
  • Myocardial Contraction / physiology*
  • Reproducibility of Results
  • Rotation
  • Sensitivity and Specificity
  • Systole
  • Ventricular Function, Left / physiology*