Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2013 Aug 1:458-460:451-8.
doi: 10.1016/j.scitotenv.2013.04.056. Epub 2013 May 17.

Study on the leaching of phthalates from polyethylene terephthalate bottles into mineral water

Affiliations
Comparative Study

Study on the leaching of phthalates from polyethylene terephthalate bottles into mineral water

Szilvia Keresztes et al. Sci Total Environ. .

Abstract

Carbonated and non-carbonated mineral water samples bottled in 0.5-L, 1.5-L and 2.0-L polyethylene terephthalate (PET) containers belonging to three different water brands commercialized in Hungary were studied in order to determine their phthalate content by gas chromatography-mass spectrometry. Among the six investigated phthalates, diisobutyl phthalate, di-n-butyl-phthalate, benzyl-butyl phthalate and di(2-ethyl-hexyl) phthalate (DEHP) were determined in non-carbonated samples as follows: <3.0 ng L(-1)-0.2 μg L(-1), <6.6 ng L(-1)-0.8 μg L(-1), <6.0 ng L(-1)-0.1 μg L(-1) and <16.0 ng L(-1)-1.7 μg L(-1), respectively. Any of the above-mentioned phthalate esters could be detected in carbonated mineral water samples. DEHP was the most abundant phthalate in the investigated samples. It could be detected after 44 days of storage at 22 °C and its leaching was the most pronounced when samples were stored over 1200 days. Mineral water purchased in PET bottles of 0.5L had the highest phthalate concentrations compared to those obtained for waters of the identical brand bottled in 1.5-L or 2.0-L PET containers due to the higher surface/volume ratio. No clear trend could be established for phthalate leaching when water samples were kept at higher temperatures (max. 60 °C) showing improper storage conditions. Phthalate determination by pyrolysis-gas chromatography/mass spectrometric measurements in the plastic material as well as in the aqueous phase proved the importance of the quality of PET raw material used for the production of the pre-form (virgin vs. polymer containing recycled PET).

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms