Higher dose dobutamine stress MR imaging in repaired Tetralogy of Fallot: observer variance of volumetric assessment compared with normal volunteers

J Magn Reson Imaging. 2013 Dec;38(6):1356-61. doi: 10.1002/jmri.24103. Epub 2013 May 23.

Abstract

Purpose: To investigate changes in image quality and observer variance between rest and higher-dose dobutamine stress MR imaging (DS-MR) in tetralogy of Fallot (TOF) patients and in a group of normal healthy volunteers using both axial and short axis orientation for cardiac volumetric assessment.

Materials and methods: Eighteen adult patients (age 34 ± 13) with TOF and severe pulmonary regurgitation and 10 healthy volunteers underwent ventricular MR volumetry at baseline and during dobutamine infusion of 10 μg/kg/min and 20 μg/kg/min. Inter-observer and intra-observer agreement was calculated by coefficient of variance (COV).

Results: Inter-observer comparison showed good agreement for left ventricle (LV) and right ventricle (RV) end-diastolic volumes at rest and both stress levels in TOF patients (axial geometry) and in normal volunteers (short axis). During dobutamine stress, the COV in TOF patients increased for LV end-systolic volume (LV-ESV) with each level, suggesting less agreement between observers. In contrast, RV-ESV was much more comparable with a COV < 10 at each condition. All volumetric measurements in normal volunteers showed good inter-observer agreement. Excellent intra-observer agreement could be seen for all volumetric parameters with COV levels below 7.

Conclusion: Volumetric assessment during DS-MR shows excellent inter-observer agreement, except for LV-ESV in the TOF patients at higher doses of dobutamine. The axial geometry appears to be reproducible for assessment of RV parameters, and could be considered superior to short axis imaging in patients with repaired TOF.

Keywords: Dobutamine stress magnetic resonance imaging (DS-MR); Tetralogy of Fallot (TOF).

Publication types

  • Comparative Study
  • Controlled Clinical Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Cardiotonic Agents / administration & dosage
  • Dobutamine / administration & dosage*
  • Dose-Response Relationship, Drug
  • Exercise Test / methods*
  • Female
  • Humans
  • Image Enhancement / methods
  • Imaging, Three-Dimensional / methods*
  • Magnetic Resonance Imaging / methods*
  • Male
  • Observer Variation
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Tetralogy of Fallot / pathology*
  • Tetralogy of Fallot / surgery*
  • Treatment Outcome

Substances

  • Cardiotonic Agents
  • Dobutamine