Validity and reliability of radiological methods to assess proximal hip geometry in children with cerebral palsy: a systematic review

Dev Med Child Neurol. 2013 Dec;55(12):1089-102. doi: 10.1111/dmcn.12169. Epub 2013 Jun 4.

Abstract

Aim: The aim of this systematic review was to assess the current validity and reliability of radiological methods used to measure proximal hip geometry in children with cerebral palsy.

Method: A search was conducted using relevant keywords and inclusion/exclusion criteria of the MEDLINE, CINALH Plus, Embase, Web of Science, Academic Search Premier, The Cochrane Library, and PsychINFO databases.

Results: The migration percentage using X-rays showed excellent reliability and concurrent validity with three-dimensional (3D) measurements from computed tomography (CT) scans. The acetabular index, measured using X-rays had good reliability but moderate concurrent validity with 3D CT measurements; 3D CT scan indexes had greater reliability. The measurement of the neck shaft angle using X-rays showed excellent concurrent validity with measurements from 3D CT scans and excellent reliability. Regarding femoral anteversion, one study found an excellent correlation between two-dimensional CT and clinical assessment and excellent reliability. Two others showed less evidence for the use of CT ultrasounds.

Interpretation: Most of the X-ray-based measurements showed good to excellent metrological properties. More metrological evidence is needed for the assessment of femoral anteversion. Magnetic resonance imaging and ultrasound-based measurements have great potential although very little metrological evidence is available.

Publication types

  • Review
  • Systematic Review

MeSH terms

  • Cerebral Palsy / pathology*
  • Child
  • Databases, Factual / statistics & numerical data
  • Hip / diagnostic imaging
  • Hip / pathology*
  • Hip Injuries / diagnosis
  • Hip Injuries / etiology
  • Humans
  • Imaging, Three-Dimensional
  • Magnetic Resonance Imaging*
  • Reproducibility of Results
  • Tomography, X-Ray Computed*