A comparison of the steady-state pharmacokinetic and pharmacodynamic profiles of 100 and 200 U/mL formulations of ultra-long-acting insulin degludec

Clin Drug Investig. 2013 Jul;33(7):515-21. doi: 10.1007/s40261-013-0096-7.

Abstract

Background and objective: Insulin degludec (IDeg) is a new-generation basal insulin that forms soluble multi-hexamers upon subcutaneous injection, resulting in a depot from which IDeg monomers are slowly and continuously absorbed to provide an ultra-long action profile. This double-blind, crossover, randomized study compared the pharmacokinetic and pharmacodynamic properties between IDeg 100 U/mL (U100) and IDeg 200 U/mL (U200) under steady-state (SS) conditions in subjects with type 1 diabetes mellitus.

Methods: Participants (n = 33 adults) underwent 8-day treatment periods with 0.4 U/kg IDeg U100 and IDeg U200 given once daily with insulin aspart at mealtimes. On day 8, a 26-h euglycaemic glucose clamp (5.5 mmol/L) was performed.

Results: The concentration-time profiles of IDeg U100 and IDeg U200 were similar, and a post-hoc analysis showed bioequivalence between these formulations, as the 90 % confidence intervals (CIs) of the U200/U100 ratios for area under the steady-state serum IDeg concentration-time curve during a dosing interval (τ; 0-24 h) (AUCτ,SS,IDeg) (0.99 [0.91-1.07]) and maximum steady-state IDeg concentration during a dosing interval (τ) (C max,SS,IDeg) (0.93 [0.84-1.02]) were within the interval 0.80-1.25. Comparable glucose infusion rates (GIR) were observed for IDeg U100 and IDeg U200 (AUCτ,SS,GIR [mg/kg]: 2,255 vs. 2,123) and the mean ratio (95 % CI) of IDeg U200/U100 for the primary endpoint (AUCτ,SS,GIR) was 0.94 [0.86-1.03]. For both formulations, the glucose-lowering effect of IDeg was evenly distributed between the first and second 12 h post-dosing (U100: AUC12,SS,GIR/AUC24,SS,GIR = 48 %; U200: AUC12,SS,GIR/AUC24,SS,GIR = 46 %). Both formulations were well tolerated, and no safety events of significance were identified.

Conclusion: IDeg U100 and U200 formulations are bioequivalent and have similar pharmacodynamic profiles at SS, implying that they can be used interchangeably in clinical practice.

Publication types

  • Comparative Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Area Under Curve
  • Cross-Over Studies
  • Double-Blind Method
  • Female
  • Humans
  • Insulin, Long-Acting / administration & dosage*
  • Insulin, Long-Acting / pharmacokinetics
  • Insulin, Long-Acting / pharmacology
  • Male
  • Middle Aged

Substances

  • Insulin, Long-Acting
  • insulin degludec