Objectives: To investigate the impact of prostate computed diffusion-weighted imaging (DWI) on image quality and tumour detection.

Methods: Forty-nine patients underwent 3-T magnetic resonance imaging using a pelvic phased-array coil before prostatectomy, including DWI with b values of 50 and 1,000 s/mm(2). Computed DW images with b value 1,500 s/mm(2) were generated from the lower b-value images. Directly acquired b-1,500 DW images were obtained in 39 patients. Two radiologists independently assessed DWI for image quality measures and location of the dominant lesion. A third radiologist measured tumour-to-peripheral-zone (PZ) contrast. Pathological findings from prostatectomy served as the reference standard.

Results: Direct and computed b-1,500 DWI showed better suppression of benign prostate tissue than direct b-1,000 DWI for both readers (P ≤ 0.024). However, computed b-1,500 DWI showed less distortion and ghosting than direct b-1,000 and direct b-1,500 DWI for both readers (P ≤ 0.067). Direct and computed b-1,500 images showed better sensitivity and positive predictive value (PPV) for tumour detection than direct b-1,000 images for both readers (P ≤ 0.062), with no difference in sensitivity or PPV between direct and computed b-1,500 images (P ≥ 0.180). Tumour-to-PZ contrast was greater on computed b-1,500 than on either direct DWI set (P < 0.001).

Conclusion: Computed DWI of the prostate using b value ≥1,000 s/mm(2) improves image quality and tumour detection compared with acquired standard b-value images.

Key points: • Diffusion weighted MRI is increasingly used for diagnosing and assessing prostate carcinoma. • Prostate computed DWI can extrapolate high b-value images from lower b values. • Computed DWI provides greater suppression of benign tissue than lower b-value images. • Computed DWI provides less distortion and artefacts than images using same b value. • Computed DWI provides better diagnostic performance than lower b-value images.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Aged, 80 and over
  • Diffusion Magnetic Resonance Imaging / methods*
  • Humans
  • Image Interpretation, Computer-Assisted / methods*
  • Male
  • Middle Aged
  • Prostate / pathology*
  • Prostate / surgery
  • Prostatectomy
  • Prostatic Neoplasms / diagnosis*
  • Prostatic Neoplasms / surgery
  • Retrospective Studies