One number does not fit all: mapping local variations in resolution in cryo-EM reconstructions
- PMID: 23954653
- PMCID: PMC3837392
- DOI: 10.1016/j.jsb.2013.08.002
One number does not fit all: mapping local variations in resolution in cryo-EM reconstructions
Abstract
The resolution of density maps from single particle analysis is usually measured in terms of the highest spatial frequency to which consistent information has been obtained. This calculation represents an average over the entire reconstructed volume. In practice, however, substantial local variations in resolution may occur, either from intrinsic properties of the specimen or for technical reasons such as a non-isotropic distribution of viewing orientations. To address this issue, we propose the use of a space-frequency representation, the short-space Fourier transform, to assess the quality of a density map, voxel-by-voxel, i.e. by local resolution mapping. In this approach, the experimental volume is divided into small subvolumes and the resolution determined for each of them. It is illustrated in applications both to model data and to experimental density maps. Regions with lower-than-average resolution may be mobile components or ones with incomplete occupancy or result from multiple conformational states. To improve the interpretability of reconstructions, we propose an adaptive filtering approach that reconciles the resolution to which individual features are calculated with the results of the local resolution map.
Keywords: Cryo-electron microscopy; Image heterogeneity; Masking; Resolution; Short-space Fourier transform; Three-dimensional reconstruction.
Published by Elsevier Inc.
Figures
Similar articles
-
Automated particle picking for low-contrast macromolecules in cryo-electron microscopy.J Struct Biol. 2014 Apr;186(1):1-7. doi: 10.1016/j.jsb.2014.03.001. Epub 2014 Mar 6. J Struct Biol. 2014. PMID: 24607413 Free PMC article.
-
Rotationally invariant image representation for viewing direction classification in cryo-EM.J Struct Biol. 2014 Apr;186(1):153-66. doi: 10.1016/j.jsb.2014.03.003. Epub 2014 Mar 12. J Struct Biol. 2014. PMID: 24631969 Free PMC article.
-
Quantifying the local resolution of cryo-EM density maps.Nat Methods. 2014 Jan;11(1):63-5. doi: 10.1038/nmeth.2727. Epub 2013 Nov 10. Nat Methods. 2014. PMID: 24213166 Free PMC article.
-
Refinement of Atomic Structures Against cryo-EM Maps.Methods Enzymol. 2016;579:277-305. doi: 10.1016/bs.mie.2016.05.033. Epub 2016 Jun 24. Methods Enzymol. 2016. PMID: 27572731 Review.
-
Ribosome dynamics: insights from atomic structure modeling into cryo-electron microscopy maps.Annu Rev Biophys Biomol Struct. 2006;35:299-317. doi: 10.1146/annurev.biophys.35.040405.101950. Annu Rev Biophys Biomol Struct. 2006. PMID: 16689638 Review.
Cited by
-
Sub-2 Angstrom resolution structure determination using single-particle cryo-EM at 200 keV.J Struct Biol X. 2020 Feb 28;4:100020. doi: 10.1016/j.yjsbx.2020.100020. eCollection 2020. J Struct Biol X. 2020. PMID: 32647824 Free PMC article.
-
Atomic model for the membrane-embedded VO motor of a eukaryotic V-ATPase.Nature. 2016 Nov 3;539(7627):118-122. doi: 10.1038/nature19828. Epub 2016 Oct 24. Nature. 2016. PMID: 27776355 Free PMC article.
-
Structural basis for backtracking by the SARS-CoV-2 replication-transcription complex.bioRxiv [Preprint]. 2021 Mar 14:2021.03.13.435256. doi: 10.1101/2021.03.13.435256. bioRxiv. 2021. Update in: Cell. 2020 Sep 17;182(6):1560-1573.e13. doi: 10.1016/j.cell.2020.07.033 Update in: Proc Natl Acad Sci U S A. 2021 May 11;118(19):e2102516118. doi: 10.1073/pnas.2102516118 PMID: 33758867 Free PMC article. Updated. Preprint.
-
Improvement of cryo-EM maps by density modification.Nat Methods. 2020 Sep;17(9):923-927. doi: 10.1038/s41592-020-0914-9. Epub 2020 Aug 17. Nat Methods. 2020. PMID: 32807957 Free PMC article.
-
Structural basis for transcription activation by Crl through tethering of σS and RNA polymerase.Proc Natl Acad Sci U S A. 2019 Sep 17;116(38):18923-18927. doi: 10.1073/pnas.1910827116. Epub 2019 Sep 4. Proc Natl Acad Sci U S A. 2019. PMID: 31484766 Free PMC article.
References
-
- Cardone G, Grünewald K, Steven AC. A resolution criterion for electron tomography based on cross-validation. J Struct Biol. 2005;151:117–129. - PubMed
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
