Skip to main page content
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Filters applied. Clear all
Randomized Controlled Trial
. 2013 Oct 17;369(16):1491-501.
doi: 10.1056/NEJMoa1303342. Epub 2013 Aug 30.

Tiotropium Respimat Inhaler and the Risk of Death in COPD

Collaborators, Affiliations
Free article
Randomized Controlled Trial

Tiotropium Respimat Inhaler and the Risk of Death in COPD

Robert A Wise et al. N Engl J Med. .
Free article

Abstract

Background: Tiotropium delivered at a dose of 5 μg with the Respimat inhaler showed efficacy similar to that of 18 μg of tiotropium delivered with the HandiHaler inhalation device in placebo-controlled trials involving patients with chronic obstructive pulmonary disease (COPD). Although tiotropium HandiHaler was associated with reduced mortality, as compared with placebo, more deaths were reported with tiotropium Respimat than with placebo.

Methods: In this randomized, double-blind, parallel-group trial involving 17,135 patients with COPD, we evaluated the safety and efficacy of tiotropium Respimat at a once-daily dose of 2.5 μg or 5 μg, as compared with tiotropium HandiHaler at a once-daily dose of 18 μg. Primary end points were the risk of death (noninferiority study, Respimat at a dose of 5 μg or 2.5 μg vs. HandiHaler) and the risk of the first COPD exacerbation (superiority study, Respimat at a dose of 5 μg vs. HandiHaler). We also assessed cardiovascular safety, including safety in patients with stable cardiac disease.

Results: During a mean follow-up of 2.3 years, Respimat was noninferior to HandiHaler with respect to the risk of death (Respimat at a dose of 5 μg vs. HandiHaler: hazard ratio, 0.96; 95% confidence interval [CI], 0.84 to 1.09; Respimat at a dose of 2.5 μg vs. HandiHaler: hazard ratio, 1.00; 95% CI, 0.87 to 1.14) and not superior to HandiHaler with respect to the risk of the first exacerbation (Respimat at a dose of 5 μg vs. HandiHaler: hazard ratio, 0.98; 95% CI, 0.93 to 1.03). Causes of death and incidences of major cardiovascular adverse events were similar in the three groups.

Conclusions: Tiotropium Respimat at a dose of 5 μg or 2.5 μg had a safety profile and exacerbation efficacy similar to those of tiotropium HandiHaler at a dose of 18 μg in patients with COPD. (Funded by Boehringer Ingelheim; TIOSPIR ClinicalTrials.gov number, NCT01126437.).

Comment in

Similar articles

See all similar articles

Cited by 112 articles

See all "Cited by" articles

Publication types

MeSH terms

Associated data

LinkOut - more resources

Feedback