Determination of 48 fragrance allergens in toys using GC with ion trap MS/MS

J Sep Sci. 2013 Nov;36(21-22):3534-49. doi: 10.1002/jssc.201300586. Epub 2013 Oct 9.

Abstract

This paper presents a method for the simultaneous determination of 48 fragrance allergens in four types of toys (plastic toys, play clays, plush toys, and paper toys) based on GC with ion trap MS/MS. Compared with single-stage MS, MS/MS is superior in terms of the qualification and quantification of a large range of compounds in complicated matrices. Procedures for extraction and purification were optimized for each toy type. The method proved to be linear over a wide range of concentrations for all analytes with correlation coefficients between 0.9768 and 0.9999. Validation parameters, namely, LODs and LOQs, ranged from 0.005-5.0 and from 0.02-20 mg/kg, respectively. Average recoveries of target compounds (spiked at three concentration levels) were in the range of 79.5-109.1%. Intraday and interday repeatabilities of the proposed method varied from 0.7-10.5% and from 3.1-13.4%, respectively. The proposed method was used to monitor fragrance allergens in commercial toy products. Our findings indicate that this method is an accurate and effective technique for analyzing fragrance allergens in materials composed of complex components.

Keywords: Fragrance allergens; Gas chromatography; Ion trap MS/MS; Toys.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Allergens / analysis*
  • Chromatography, Gas
  • Perfume / chemistry*
  • Play and Playthings*
  • Tandem Mass Spectrometry

Substances

  • Allergens
  • Perfume