Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 Nov 15;27(21):2425-31.
doi: 10.1002/rcm.6705.

Constructing a mass measurement error surface to improve automatic annotations in liquid chromatography/mass spectrometry based metabolomics

Affiliations

Constructing a mass measurement error surface to improve automatic annotations in liquid chromatography/mass spectrometry based metabolomics

Nir Shahaf et al. Rapid Commun Mass Spectrom. .

Abstract

Rationale: Estimation of mass measurement accuracy is an elementary step in the application of mass spectroscopy (MS) data towards metabolite annotations and has been addressed several times in the past. However, the reproducibility of mass measurements over a diverse set of analytes and in variable operating conditions, which are common in high-throughput metabolomics studies, has, to the best of our knowledge, not been addressed so far.

Methods: A method to automatically extract mass measurement errors from a large data set of measurements made on a quadrupole time-of-flight (QTOF) MS instrument has been developed. The size of the data processed in this study has enabled us to use a statistical data driven approach to build a model which reliably predicts the confidence interval of the absolute mass measurement error based on individual ion peak conditions in a fast, high-throughput manner.

Results: We show that our model predictions are reproducible in external datasets generated in similar, but not identical conditions, and have demonstrated the advantage of our approach over the common practice of fixed mass measurement error limits.

Conclusions: Outlined is an approach which can promote a more rational use of MS technology by automatically evaluating the absolute mass measurement error based on the individual peak conditions. The immediate application of our method is integration in high-throughput peak annotation pipelines for database searches.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources