Computed tomography angiography and perfusion to assess coronary artery stenosis causing perfusion defects by single photon emission computed tomography: the CORE320 study

Eur Heart J. 2014 May;35(17):1120-30. doi: 10.1093/eurheartj/eht488. Epub 2013 Nov 19.

Abstract

Aims: To evaluate the diagnostic power of integrating the results of computed tomography angiography (CTA) and CT myocardial perfusion (CTP) to identify coronary artery disease (CAD) defined as a flow limiting coronary artery stenosis causing a perfusion defect by single photon emission computed tomography (SPECT).

Methods and results: We conducted a multicentre study to evaluate the accuracy of integrated CTA-CTP for the identification of patients with flow-limiting CAD defined by ≥50% stenosis by invasive coronary angiography (ICA) with a corresponding perfusion deficit on stress single photon emission computed tomography (SPECT/MPI). Sixteen centres enroled 381 patients who underwent combined CTA-CTP and SPECT/MPI prior to conventional coronary angiography. All four image modalities were analysed in blinded independent core laboratories. The prevalence of obstructive CAD defined by combined ICA-SPECT/MPI and ICA alone was 38 and 59%, respectively. The patient-based diagnostic accuracy defined by the area under the receiver operating characteristic curve (AUC) of integrated CTA-CTP for detecting or excluding flow-limiting CAD was 0.87 [95% confidence interval (CI): 0.84-0.91]. In patients without prior myocardial infarction, the AUC was 0.90 (95% CI: 0.87-0.94) and in patients without prior CAD the AUC for combined CTA-CTP was 0.93 (95% CI: 0.89-0.97). For the combination of a CTA stenosis ≥50% stenosis and a CTP perfusion deficit, the sensitivity, specificity, positive predictive, and negative predicative values (95% CI) were 80% (72-86), 74% (68-80), 65% (58-72), and 86% (80-90), respectively. For flow-limiting disease defined by ICA-SPECT/MPI, the accuracy of CTA was significantly increased by the addition of CTP at both the patient and vessel levels.

Conclusions: The combination of CTA and perfusion correctly identifies patients with flow limiting CAD defined as ≥50 stenosis by ICA causing a perfusion defect by SPECT/MPI.

Keywords: Atherosclerosis; Imaging; Ischemia; Multislice computed tomography; Perfusion.

Publication types

  • Comparative Study
  • Evaluation Study
  • Multicenter Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Coronary Stenosis / diagnostic imaging*
  • Coronary Stenosis / physiopathology
  • Female
  • Hemodynamics / physiology
  • Humans
  • Male
  • Middle Aged
  • Multidetector Computed Tomography
  • Myocardial Perfusion Imaging / methods
  • Prospective Studies
  • ROC Curve
  • Sensitivity and Specificity
  • Tomography, Emission-Computed, Single-Photon / methods*