Prevalence, significance, and management of aortic insufficiency in continuous flow left ventricular assist device recipients
- PMID: 24415682
- DOI: 10.1161/CIRCHEARTFAILURE.113.000878
Prevalence, significance, and management of aortic insufficiency in continuous flow left ventricular assist device recipients
Abstract
Background: Aortic insufficiency (AI) is increasingly recognized as a complication of continuous flow left ventricular assist device support; however, its long-term prevalence, clinical significance, and efficacy of potential interventions are not well known.
Methods and results: We studied the prevalence and management of AI in 232 patients with continuous flow left ventricular assist device at our institution. Patients with aortic valve (AV) surgery before left ventricular assist device implantation were excluded from analysis. To examine the prevalence of de novo AI, patients without preoperative AI were divided into a retrospective and a prospective cohort based on whether a dedicated speed optimization study had been performed at the time of discharge. Forty-three patients underwent AV repair at the time of implant, and 3 subsequently developed greater than mild AI. In patients without surgical AV manipulation and no AI at the time of implant, Kaplan-Meier analysis revealed that freedom from greater than mild de novo AI at 1 year was 77.6±4.2%, and that at least moderate AI is expected to develop in 37.6±13.3% after 3 years. Nonopening of the AV was strongly associated with de novo AI development in patients without prospective discharge speed optimization. Seven of 21 patients with at least moderate AI developed symptomatic heart failure requiring surgical intervention.
Conclusions: AI is common in patients with continuous flow left ventricular assist devices and may lead to clinical decompensation requiring surgical correction. The prevalence of AI is substantially less in patients whose AV opens, and optimized loading conditions may reduce AI prevalence in those patients in whom AV opening cannot be achieved.
Keywords: aortic valve insufficiency; echocardiography; heart-assist devices.
Similar articles
-
Natural history and clinical effect of aortic valve regurgitation after left ventricular assist device implantation.J Thorac Cardiovasc Surg. 2013 May;145(5):1373-9. doi: 10.1016/j.jtcvs.2012.11.066. Epub 2013 Jan 8. J Thorac Cardiovasc Surg. 2013. PMID: 23312101
-
Durability of central aortic valve closure in patients with continuous flow left ventricular assist devices.J Thorac Cardiovasc Surg. 2014 Jan;147(1):344-8. doi: 10.1016/j.jtcvs.2012.09.098. Epub 2012 Dec 13. J Thorac Cardiovasc Surg. 2014. PMID: 23246052
-
Surgical correction of aortic valve insufficiency after left ventricular assist device implantation.J Thorac Cardiovasc Surg. 2013 Nov;146(5):1247-52. doi: 10.1016/j.jtcvs.2013.05.019. Epub 2013 Jul 16. J Thorac Cardiovasc Surg. 2013. PMID: 23870154
-
Preoperative Prediction of Aortic Insufficiency During Ventricular Assist Device Treatment.Int Heart J. 2016;57(1):3-10. doi: 10.1536/ihj.15-250. Epub 2016 Jan 6. Int Heart J. 2016. PMID: 26742702 Review.
-
Continuous-Flow Left Ventricular Assist Devices and the Aortic Valve: Interactions, Issues, and Surgical Therapy.Curr Heart Fail Rep. 2020 Aug;17(4):97-105. doi: 10.1007/s11897-020-00464-0. Curr Heart Fail Rep. 2020. PMID: 32488504 Review.
Cited by
-
Advanced Heart Failure: Therapeutic Options and Challenges in the Evolving Field of Left Ventricular Assist Devices.J Cardiovasc Dev Dis. 2024 Feb 16;11(2):61. doi: 10.3390/jcdd11020061. J Cardiovasc Dev Dis. 2024. PMID: 38392275 Free PMC article. Review.
-
Cellular and Molecular Mechanisms Activated by a Left Ventricular Assist Device.Int J Mol Sci. 2023 Dec 24;25(1):288. doi: 10.3390/ijms25010288. Int J Mol Sci. 2023. PMID: 38203459 Free PMC article. Review.
-
Catheter Ablation for Tachyarrhythmias in Left Ventricular Assist Device Recipients: Clinical Significance and Technical Tips.J Clin Med. 2023 Nov 15;12(22):7111. doi: 10.3390/jcm12227111. J Clin Med. 2023. PMID: 38002723 Free PMC article. Review.
-
The Impact of Left Ventricular Assist Device Outflow Graft Positioning on Aortic Hemodynamics: Improving Flow Dynamics to Mitigate Aortic Insufficiency.Biomimetics (Basel). 2023 Oct 1;8(6):465. doi: 10.3390/biomimetics8060465. Biomimetics (Basel). 2023. PMID: 37887596 Free PMC article.
-
Cardiac mechanics and reverse remodelling under mechanical support from left ventricular assist devices.Front Cardiovasc Med. 2023 Aug 2;10:1212875. doi: 10.3389/fcvm.2023.1212875. eCollection 2023. Front Cardiovasc Med. 2023. PMID: 37600037 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical