Increasing shape modelling accuracy by adjusting for subject positioning: an application to the analysis of radiographic proximal femur symmetry using data from the Osteoarthritis Initiative

Bone. 2014 Apr;61(100):64-70. doi: 10.1016/j.bone.2014.01.003. Epub 2014 Jan 14.

Abstract

In total hip arthroplasty, the shape of the contra-lateral femur frequently serves as a template for preoperative planning. Previous research on contra-lateral femoral symmetry has been based on conventional hip geometric measurements (which reduce shape to a series of linear measurements) and did not take the effect of subject positioning on radiographic femur shape into account. The aim of this study was to analyse proximal femur symmetry based on statistical shape models (SSMs) which quantify global femoral shape while also adjusting for differences in subject positioning during image acquisition. We applied our recently developed fully automatic shape model matching (FASMM) system to automatically segment the proximal femur from AP pelvic radiographs to generate SSMs of the proximal femurs of 1258 Caucasian females (mean age: 61.3 SD=9.0). We used a combined SSM (capturing the left and right femurs) to identify and adjust for shape variation attributable to subject positioning as well as a single SSM (including all femurs as left femurs) to analyse proximal femur symmetry. We also calculated conventional hip geometric measurements (head diameter, neck width, shaft width and neck-shaft angle) using the output of the FASMM system. The combined SSM revealed two modes that were clearly attributable to subject positioning. The average difference (mean point-to-curve distance) between left and right femur shape was 1.0mm before and 0.8mm after adjusting for these two modes. The automatic calculation of conventional hip geometric measurements after adjustment gave an average absolute percent asymmetry of within 3.1% and an average absolute difference of within 1.1mm or 2.9° for all measurements. We conclude that (i) for Caucasian females the global shape of the right and left proximal femurs is symmetric without isolated locations of asymmetry; (ii) a combined left-right SSM can be used to adjust for radiographic shape variation due to subject positioning; and (iii) adjusting for subject positioning increases the accuracy of predicting the shape of the contra-lateral hip.

Keywords: Hip morphology; Osteoarthritis; Osteoporosis; Preoperative planning; Statistical shape model; Total hip arthroplasty.

Publication types

  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Databases, Factual
  • Female
  • Femur / diagnostic imaging*
  • Humans
  • Image Processing, Computer-Assisted / methods*
  • Middle Aged
  • Models, Statistical*
  • Osteoarthritis / pathology
  • Osteoarthritis / surgery
  • Patient Positioning
  • Radiography
  • Surgery, Computer-Assisted / methods*