Whole-body MRI for initial staging of paediatric lymphoma: prospective comparison to an FDG-PET/CT-based reference standard

Eur Radiol. 2014 May;24(5):1153-65. doi: 10.1007/s00330-014-3114-0. Epub 2014 Feb 23.

Abstract

Objective: To compare whole-body MRI, including diffusion-weighted imaging (whole-body MRI-DWI), with FDG-PET/CT for staging newly diagnosed paediatric lymphoma.

Methods: A total of 36 children with newly diagnosed lymphoma prospectively underwent both whole-body MRI-DWI and FDG-PET/CT. Whole-body MRI-DWI was successfully performed in 33 patients (mean age 13.9 years). Whole-body MRI-DWI was independently evaluated by two blinded observers. After consensus reading, an unblinded expert panel evaluated the discrepant findings between whole-body MRI-DWI and FDG-PET/CT and used bone marrow biopsy, other imaging data and clinical information to derive an FDG-PET/CT-based reference standard.

Results: Interobserver agreement of whole-body MRI-DWI was good [all nodal sites together (κ = 0.79); all extranodal sites together (κ = 0.69)]. There was very good agreement between the consensus whole-body MRI-DWI- and FDG-PET/CT-based reference standard for nodal (κ = 0.91) and extranodal (κ = 0.94) staging. The sensitivity and specificity of consensus whole-body MRI-DWI were 93 % and 98 % for nodal staging and 89 % and 100 % for extranodal staging, respectively. Following removal of MRI reader errors, the disease stage according to whole-body MRI-DWI agreed with the reference standard in 28 of 33 patients.

Conclusions: Our results indicate that whole-body MRI-DWI is feasible for staging paediatric lymphoma and could potentially serve as a good radiation-free alternative to FDG-PET/CT.

Keypoints: • Accurate staging is important for treatment planning and assessing prognosis • Whole-body MRI-DWI could be a good radiation-free alternative to FDG-PET/CT • Interobserver agreement of whole-body MRI-DWI is good • Agreement between whole-body MRI and the FDG-PET/CT reference standard is good • Most discrepancies were caused by suboptimal accuracy of size measurements on MRI.

Publication types

  • Clinical Trial
  • Comparative Study
  • Multicenter Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adolescent
  • Child
  • Diffusion Magnetic Resonance Imaging / methods*
  • Female
  • Fluorodeoxyglucose F18*
  • Humans
  • Lymphoma / diagnostic imaging*
  • Male
  • Neoplasm Staging
  • Observer Variation
  • Positron-Emission Tomography / methods*
  • Prognosis
  • Prospective Studies
  • Radiopharmaceuticals*
  • Reference Standards
  • Sensitivity and Specificity
  • Whole Body Imaging

Substances

  • Radiopharmaceuticals
  • Fluorodeoxyglucose F18