Official American Thoracic Society technical standards: spirometry in the occupational setting
- PMID: 24735032
- DOI: 10.1164/rccm.201402-0337ST
Official American Thoracic Society technical standards: spirometry in the occupational setting
Abstract
Purpose: This document addresses aspects of the performance and interpretation of spirometry that are particularly important in the workplace, where inhalation exposures can affect lung function and cause or exacerbate lung diseases, such as asthma, chronic obstructive pulmonary disease, or fibrosis.
Methods: Issues that previous American Thoracic Society spirometry statements did not adequately address with respect to the workplace were identified for systematic review. Medline 1950-2012 and Embase 1980-2012 were searched for evidence related to the following: training for spirometry technicians; testing posture; appropriate reference values to use for Asians in North America; and interpretative strategies for analyzing longitudinal change in lung function. The evidence was reviewed and technical recommendations were developed.
Results: Spirometry performed in the work setting should be part of a comprehensive workplace respiratory health program. Effective technician training and feedback can improve the quality of spirometry testing. Posture-related changes in FEV1 and FVC, although small, may impact interpretation, so testing posture should be kept consistent and documented on repeat testing. Until North American Asian-specific equations are developed, applying a correction factor of 0.88 to white reference values is considered reasonable when testing Asian American individuals in North America. Current spirometry should be compared with previous tests. Excessive loss in FEV1 over time should be evaluated using either a percentage decline (15% plus loss expected due to aging) or one of the other approaches discussed, taking into consideration testing variability, worker exposures, symptoms, and other clinical information.
Conclusions: Important aspects of workplace spirometry are discussed and recommendations are provided for the performance and interpretation of workplace spirometry.
Comment in
-
Spirometry in the occupational setting.Am J Respir Crit Care Med. 2014 Aug 1;190(3):352-3. doi: 10.1164/rccm.201405-0813LE. Am J Respir Crit Care Med. 2014. PMID: 25084266 No abstract available.
-
Reply: Spirometry in the occupational setting.Am J Respir Crit Care Med. 2014 Aug 1;190(3):353-4. doi: 10.1164/rccm.201406-1063LE. Am J Respir Crit Care Med. 2014. PMID: 25084267 No abstract available.
Similar articles
-
ACOEM position statement. Spirometry in the occupational setting. American College of Occupational and Environmental Medicine.J Occup Environ Med. 2000 Mar;42(3):228-45. doi: 10.1097/00043764-200003000-00003. J Occup Environ Med. 2000. PMID: 10738702 Review.
-
Longitudinal assessment of lung function decline in the occupational setting.Curr Opin Allergy Clin Immunol. 2015 Apr;15(2):145-9. doi: 10.1097/ACI.0000000000000153. Curr Opin Allergy Clin Immunol. 2015. PMID: 25961387 Review.
-
Spirometry in the occupational setting.Am J Respir Crit Care Med. 2014 Aug 1;190(3):352-3. doi: 10.1164/rccm.201405-0813LE. Am J Respir Crit Care Med. 2014. PMID: 25084266 No abstract available.
-
Periodic spirometry in occupational setting: improving quality, accuracy, and precision.J Occup Environ Med. 2011 Oct;53(10):1205-9. doi: 10.1097/JOM.0b013e31823078b8. J Occup Environ Med. 2011. PMID: 21915065
-
Reply: Spirometry in the occupational setting.Am J Respir Crit Care Med. 2014 Aug 1;190(3):353-4. doi: 10.1164/rccm.201406-1063LE. Am J Respir Crit Care Med. 2014. PMID: 25084267 No abstract available.
Cited by
-
Investigating the relationship of trunk and postural control with pulmonary functions in subacute stroke patients.Neurol Sci. 2024 Sep 7. doi: 10.1007/s10072-024-07750-y. Online ahead of print. Neurol Sci. 2024. PMID: 39243321
-
The association between declining lung function and stroke risk: insights from an observational study and Mendelian randomization.Front Neurol. 2024 Jun 7;15:1401959. doi: 10.3389/fneur.2024.1401959. eCollection 2024. Front Neurol. 2024. PMID: 38911586 Free PMC article.
-
Exploring the adverse effect of fine particulate matter (PM2.5) on wildland firefighters' pulmonary function and DNA damage.Sci Rep. 2024 Apr 4;14(1):7932. doi: 10.1038/s41598-024-58721-4. Sci Rep. 2024. PMID: 38575786 Free PMC article.
-
Indoor and ambient black carbon and fine particulate matter associations with blood biomarkers in COPD patients.Sci Total Environ. 2024 Jun 1;927:171897. doi: 10.1016/j.scitotenv.2024.171897. Epub 2024 Mar 22. Sci Total Environ. 2024. PMID: 38522542
-
How to interpret parameters of routine lung function tests in 2023?Tunis Med. 2023 Mar 5;101(3):323-333. Tunis Med. 2023. PMID: 38263920 Free PMC article. French.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical