. 2014 Oct;103(10):775-80.
doi: 10.1007/s00392-014-0713-3. Epub 2014 Apr 21.

Feasibility of sheathless transfemoral aortic valve implantation in patients with small access vessel diameters

Affiliations
Clinical Trial

Feasibility of sheathless transfemoral aortic valve implantation in patients with small access vessel diameters

Nicolas A Geis et al. Clin Res Cardiol. 2014 Oct.

Abstract

Objectives: We intended to show feasibility of sheathless transfemoral aortic valve implantation in patients with small access vessel diameters.

Background: Transcatheter aortic valve implantation (TAVI) has emerged as a valid treatment option in patients with aortic valve stenosis who are poor candidates for surgical aortic valve replacement. Few patients, who cannot undergo transfemoral or transsubclavian aortic valve implantation due to small access vessel diameters, are not suitable for transapical or direct aortic valve implantation, either.

Methods: In more than 700 transcatheter aortic valve implantations since 2008 we identified 17 patients who had to be excluded from transfemoral valve implantation due to vessel diameters <6 mm and who were no candidates for transapical or direct aortic implantation. We performed CoreValve™ implantations in these patients without the required 18F sheath to cross the vessels despite their small size (4.6-5.9 mm).

Results: Sixteen sheathless implantations were successful. In all 17 patients, bleeding during the procedure due to the smaller delivery catheter was minimal. Sixteen patients had a successful access site closure at the end of the procedure.

Conclusions: Sheathless implantation of a self-expanding aortic valve can be safely considered in selected patients with access vessel diameters below 6 mm, if transapical or direct aortic implantation is not suitable.

Similar articles

Cited by

References

    1. Clin Res Cardiol. 2014 Jan;103(1):65-72 - PubMed
    1. Clin Res Cardiol. 2013 Dec;102(12):895-903 - PubMed
    1. Clin Res Cardiol. 2014 Mar;103(3):183-90 - PubMed
    1. J Am Coll Cardiol. 2012 Aug 7;60(6):483-92 - PubMed
    1. Clin Res Cardiol. 2013 Sep;102(9):627-36 - PubMed