Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Multicenter Study
. 2014 Jun;123(6):1185-1192.
doi: 10.1097/AOG.0000000000000229.

Predictive value of cervical length measurement and fibronectin testing in threatened preterm labor

Affiliations
Multicenter Study

Predictive value of cervical length measurement and fibronectin testing in threatened preterm labor

Gert-Jan van Baaren et al. Obstet Gynecol. 2014 Jun.

Abstract

Objective: To estimate the performance of combining cervical length measurement with fetal fibronectin testing in predicting delivery in women with symptoms of preterm labor.

Methods: We conducted a prospective nationwide cohort study in all 10 perinatal centers in The Netherlands. Women with symptoms of preterm labor between 24 and 34 weeks of gestation with intact membranes were included. In all women, qualitative fibronectin testing (0.050-microgram/mL cutoff) and cervical length measurement were performed. Logistic regression was used to predict spontaneous preterm delivery within 7 days after testing. A risk less than 5%, corresponding to the risk for women with a cervical length of at least 25 mm, was considered as low risk.

Results: Between December 2009 and August 2012, 714 women were enrolled. Fibronectin results and cervical length were available for 665 women, of whom 80 (12%) delivered within 7 days. Women with a cervical length of at least 30 mm or with a cervical length between 15 and 30 mm with a negative fibronectin result were at low risk (less than 5%) of spontaneous delivery within 7 days. Fibronectin testing in case of a cervical length between 15 and 30 mm additionally classified 103 women (15% of the cohort) as low risk and 36 women (5% of the cohort) as high risk.

Conclusion: Cervical length measurement, combined with fetal fibronectin testing in case of a cervical length between 15 and 30 mm, improves identification of women with a low risk to deliver spontaneously within 7 days.

Level of evidence: II.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Slattery MM, Morrison JJ. Preterm delivery. Lancet 2002;360:1489–97.
    1. Sotiriadis A, Papatheodorou S, Kavvadias A, Makrydimas G. Transvaginal cervical length measurement for prediction of preterm birth in women with threatened preterm labor: a meta-analysis. Ultrasound Obstet Gynecol 2010;35:54–64.
    1. Gomez R, Romero R, Medina L, Nien JK, Chaiworapongsa T, Carstens M, et al.. Cervicovaginal fibronectin improves the prediction of preterm delivery based on sonographic cervical length in patients with preterm uterine contractions and intact membranes. Am J Obstet Gynecol 2005;192:350–9.
    1. Sanchez-Ramos L, Delke I, Zamora J, Kaunitz AM. Fetal fibronectin as a short-term predictor of preterm birth in symptomatic patients: a meta-analysis. Obstet Gynecol 2009;114:631–40.
    1. French NP, Hagan R, Evans SF, Mullan A, Newnham JP. Repeated antenatal corticosteroids: effects on cerebral palsy and childhood behavior. Am J Obstet Gynecol 2004;190:588–95.

Publication types