Monitoring c-reactive protein after laparoscopic colorectal surgery excludes infectious complications and allows for safe and early discharge

Surg Endosc. 2014 Oct;28(10):2939-48. doi: 10.1007/s00464-014-3556-0. Epub 2014 May 23.

Abstract

Background: Early detection of infectious complications is urgently needed in the era of DRG-based compensation. This work assessed the diagnostic accuracy of c-reactive protein (CRP) level in the detection of infectious complications after laparoscopic colorectal resection.

Methods: Laparoscopic colorectal resections were identified from a prospective database. Complications were graded according to the Dindo-Clavien classification. Surgical site infections were defined according to the Centers of Disease Control. CRP level was routinely measured until postoperative day (POD) 7. Uni- and multivariate analysis were performed. Diagnostic accuracy was evaluated using receiver operating curves.

Results: 355 patients were operated for diverticulosis (88.7%), neoplasia (6.8%), and other causes (4.5%). Mean age and body mass index were 59.8 ± 13.7 years and 26.5 ± 15 kg/m(2). Left, right, and total laparoscopic colectomies were performed in 316, 33, and 6 patients. Complications occurred in 85 patients and 16 patients (4.5%) were reoperated. Fifty-one patients (14.4%) suffered from infectious complications at a median of 6 POD, while 9 anastomoses leaked (2.7%). In multivariate analysis, presence of an abscess at surgery was predictive of an infectious complication (OR 2.5, 95% CI 1.1-5.3), as were a body mass index >30 kg/m(2) and operative time >160 min in a bootstrap analysis. Overall, CRP peaked on POD 2 and declined thereafter. Most infectious complications were apparent starting on POD 6. A CRP <56 mg/l on POD 4 had a negative predictive value of 100% (95% CI 94.9-100%) to rule out infectious complications. Above 56 mg/l, sensitivity was 100% (95% CI 0.8-1) and specificity 49% (95% CI 0.4-0.6) for the development of infectious complications in the absence of clinical signs. This translated into a remarkable diagnostic accuracy of 78% (95% CI 0.7-0.9).

Conclusion: Monitoring CRP level in laparoscopic colorectal surgery demonstrated a high diagnostic accuracy for infectious complications, thus allowing for safe and early discharge.

MeSH terms

  • Aged
  • Anastomotic Leak / etiology
  • C-Reactive Protein / metabolism*
  • Colonic Diseases / surgery*
  • Cross Infection / diagnosis*
  • Cross Infection / etiology
  • Early Diagnosis
  • Female
  • Humans
  • Laparoscopy / adverse effects*
  • Length of Stay*
  • Leukocyte Count
  • Male
  • Middle Aged
  • Patient Discharge
  • Postoperative Period
  • Prospective Studies
  • Rectal Diseases / surgery*
  • Sensitivity and Specificity

Substances

  • C-Reactive Protein