Concepts and misconceptions in corneal biomechanics
- PMID: 24857435
- DOI: 10.1016/j.jcrs.2014.04.019
Concepts and misconceptions in corneal biomechanics
Abstract
This review looks at biomechanical concepts and misconceptions related to in vivo assessment of corneal biomechanical response via air-puff deformation, including both human donor corneas and the translation of similar concepts to clinical studies. The impact of corneal viscoelasticity on interpreting clinical data is discussed, as well as the differences between 2 clinical devices that produce air puffs with distinct temporal and magnitude profiles.
Financial disclosure: Dr. Roberts is a consultant to Oculus Optikgeräte GmbH and Ziemer Ophthalmic Systems AG and has received research funding from Carl Zeiss Meditec AG as well as travel funds from Sooft Italia. She has no financial or proprietary interest in any material or method mentioned.
Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Similar articles
-
Deformation response of paired donor corneas to an air puff: intact whole globe versus mounted corneoscleral rim.J Cataract Refract Surg. 2014 Jun;40(6):888-96. doi: 10.1016/j.jcrs.2014.02.032. J Cataract Refract Surg. 2014. PMID: 24857437
-
In vivo characterization of corneal biomechanics.J Cataract Refract Surg. 2014 Jun;40(6):870-87. doi: 10.1016/j.jcrs.2014.03.021. J Cataract Refract Surg. 2014. PMID: 24857436 Review.
-
Air puff induced corneal vibrations: theoretical simulations and clinical observations.J Refract Surg. 2014 Mar;30(3):208-13. doi: 10.3928/1081597X-20140212-02. J Refract Surg. 2014. PMID: 24763727
-
Corneal biomechanical metrics and anterior segment parameters in mild keratoconus.Ophthalmology. 2010 Apr;117(4):673-9. doi: 10.1016/j.ophtha.2009.09.023. Ophthalmology. 2010. PMID: 20138369
-
Identification of biomechanical properties of the cornea: the ocular response analyzer.Curr Eye Res. 2012 Jul;37(7):553-62. doi: 10.3109/02713683.2012.669007. Epub 2012 May 4. Curr Eye Res. 2012. PMID: 22559332 Review.
Cited by
-
Biomechanical properties measured with dynamic Scheimpflug analyzer in central serous chorioretinopathy.Graefes Arch Clin Exp Ophthalmol. 2024 Jan 29. doi: 10.1007/s00417-024-06378-0. Online ahead of print. Graefes Arch Clin Exp Ophthalmol. 2024. PMID: 38285248
-
A Corneal Biomechanical Study Measured with a Scheimpflug Dynamic Analyser in Soft Contact Lens Wearers.Life (Basel). 2023 Dec 8;13(12):2313. doi: 10.3390/life13122313. Life (Basel). 2023. PMID: 38137914 Free PMC article.
-
Higher intraocular pressure is associated with slower axial growth in children with non-pathological high myopia.Eye (Lond). 2023 Dec 11. doi: 10.1038/s41433-023-02872-7. Online ahead of print. Eye (Lond). 2023. PMID: 38081936
-
Corneal biomechanics in early diagnosis of keratoconus using artificial intelligence.Graefes Arch Clin Exp Ophthalmol. 2023 Nov 9. doi: 10.1007/s00417-023-06307-7. Online ahead of print. Graefes Arch Clin Exp Ophthalmol. 2023. PMID: 37943332 Review.
-
Comparing corneal biomechanic changes among solo cataract surgery, microhook ab interno trabeculotomy and iStent implantation.Sci Rep. 2023 Nov 6;13(1):19148. doi: 10.1038/s41598-023-46709-5. Sci Rep. 2023. PMID: 37932377 Free PMC article.