Corneal biomechanical properties after LASIK, ReLEx flex, and ReLEx smile by Scheimpflug-based dynamic tonometry
- PMID: 24862302
- DOI: 10.1007/s00417-014-2667-6
Corneal biomechanical properties after LASIK, ReLEx flex, and ReLEx smile by Scheimpflug-based dynamic tonometry
Abstract
Purpose: To evaluate corneal biomechanical properties after LASIK, ReLEx flex, and the flap-free procedure ReLEx smile by Scheimpflug-based dynamic tonometry (Corvis ST) and non-contact differential tonometry (Ocular Response Analyzer, ORA).
Methods: Patients treated for high myopia (-10.5 to -5.5 diopters, spherical equivalent refraction) more than one year previously at Aarhus University Hospital were included. Treatments comprised LASIK (35 eyes), ReLEx flex (31 eyes), and ReLEx smile (29 eyes). A control group included 31 healthy eyes. Cornea-compensated IOP (IOPcc), corneal hysteresis (CH), and corneal resistance factor (CRF) were measured with ORA. Corneal applanation and deformation were registered with Corvis ST during an air-pulse.
Results: Multiple linear regression analysis showed that CH and CRF were significantly lower after all keratorefractive procedures compared to healthy controls (p < 0.05). No significant differences were observed in CH or CRF between the keratorefractive groups. Corvis ST showed no differences in radius at highest concavity (HC radius), time until first applanation (A1 Time), time until second applanation (A2 Time), and deflection length at highest concavity (HC deflection length) between groups. LASIK treated eyes had significantly shorter time until highest concavity than eyes treated with ReLEx smile (HC Time, p = 0.01). The A1 deflection length was significantly shorter in the keratorefractive groups compared to the healthy controls (p < 0.05).
Conclusions: Keratorefrative procedures alter the corneal biomechanical properties with regard to corneal hysteresis and corneal resistant factor. The flap-based LASIK and ReLEx flex and the flap-free ReLEx smile result in similar reduction in corneal biomechanics when evaluated by Corvis ST and ORA.
Similar articles
-
Changes in biomechanical properties of the cornea and intraocular pressure after myopic laser in situ keratomileusis using a femtosecond laser for flap creation determined using ocular response analyzer and Goldmann applanation tonometry.J Glaucoma. 2015 Mar;24(3):195-201. doi: 10.1097/IJG.0b013e31829da1ec. J Glaucoma. 2015. PMID: 23807345
-
Evaluation of Changes in Human Corneas After Femtosecond Laser-Assisted LASIK and Small-Incision Lenticule Extraction (SMILE) Using Non-Contact Tonometry and Ultra-High-Speed Camera (Corvis ST).Curr Eye Res. 2016 Jul;41(7):917-22. doi: 10.3109/02713683.2015.1082185. Epub 2015 Nov 10. Curr Eye Res. 2016. PMID: 26554611
-
Corvis ST Tonometer for Measuring Postoperative IOP in LASIK Patients.Optom Vis Sci. 2015 May;92(5):589-95. doi: 10.1097/OPX.0000000000000575. Optom Vis Sci. 2015. PMID: 25871871
-
Corneal Parameters in Healthy Subjects Assessed by Corvis ST.J Ophthalmic Vis Res. 2020 Feb 2;15(1):24-31. doi: 10.18502/jovr.v15i1.5936. eCollection 2020 Jan-Mar. J Ophthalmic Vis Res. 2020. PMID: 32095205 Free PMC article. Review.
-
Clinical Evaluation of Corneal Biomechanics following Laser Refractive Surgery in Myopic Eyes: A Review of the Literature.J Clin Med. 2022 Dec 28;12(1):243. doi: 10.3390/jcm12010243. J Clin Med. 2022. PMID: 36615041 Free PMC article. Review.
Cited by
-
The Importance of Using CBI-LVC for Detecting Ectasia in Post-Refractive Eyes.Beyoglu Eye J. 2023 Sep 13;8(3):237-238. doi: 10.14744/bej.2023.82542. eCollection 2023. Beyoglu Eye J. 2023. PMID: 37766770 Free PMC article. No abstract available.
-
Corneal Biomechanics After SMILE, Femtosecond-Assisted LASIK, and Photorefractive Keratectomy: A Matched Comparison Study.Transl Vis Sci Technol. 2023 Mar 1;12(3):12. doi: 10.1167/tvst.12.3.12. Transl Vis Sci Technol. 2023. PMID: 36928130 Free PMC article.
-
In Vivo Evaluation of the Effects of SMILE with Different Amounts of Stromal Ablation on Corneal Biomechanics by Optical Coherence Elastography.Diagnostics (Basel). 2022 Dec 22;13(1):30. doi: 10.3390/diagnostics13010030. Diagnostics (Basel). 2022. PMID: 36611322 Free PMC article.
-
Correlations among Corneal Biomechanical Parameters, Stiffness, and Thickness Measured Using Corvis ST and Pentacam in Patients with Ocular Hypertension.J Ophthalmol. 2022 Dec 3;2022:7387581. doi: 10.1155/2022/7387581. eCollection 2022. J Ophthalmol. 2022. PMID: 36510627 Free PMC article.
-
The Shape of Corneal Deformation Alters Air Puff-Induced Loading.Front Bioeng Biotechnol. 2022 Mar 30;10:848060. doi: 10.3389/fbioe.2022.848060. eCollection 2022. Front Bioeng Biotechnol. 2022. PMID: 35433651 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources