An analysis of electronic health record-related patient safety concerns
- PMID: 24951796
- PMCID: PMC4215044
- DOI: 10.1136/amiajnl-2013-002578
An analysis of electronic health record-related patient safety concerns
Abstract
Objective: A recent Institute of Medicine report called for attention to safety issues related to electronic health records (EHRs). We analyzed EHR-related safety concerns reported within a large, integrated healthcare system.
Methods: The Informatics Patient Safety Office of the Veterans Health Administration (VA) maintains a non-punitive, voluntary reporting system to collect and investigate EHR-related safety concerns (ie, adverse events, potential events, and near misses). We analyzed completed investigations using an eight-dimension sociotechnical conceptual model that accounted for both technical and non-technical dimensions of safety. Using the framework analysis approach to qualitative data, we identified emergent and recurring safety concerns common to multiple reports.
Results: We extracted 100 consecutive, unique, closed investigations between August 2009 and May 2013 from 344 reported incidents. Seventy-four involved unsafe technology and 25 involved unsafe use of technology. A majority (70%) involved two or more model dimensions. Most often, non-technical dimensions such as workflow, policies, and personnel interacted in a complex fashion with technical dimensions such as software/hardware, content, and user interface to produce safety concerns. Most (94%) safety concerns related to either unmet data-display needs in the EHR (ie, displayed information available to the end user failed to reduce uncertainty or led to increased potential for patient harm), software upgrades or modifications, data transmission between components of the EHR, or 'hidden dependencies' within the EHR.
Discussion: EHR-related safety concerns involving both unsafe technology and unsafe use of technology persist long after 'go-live' and despite the sophisticated EHR infrastructure represented in our data source. Currently, few healthcare institutions have reporting and analysis capabilities similar to the VA.
Conclusions: Because EHR-related safety concerns have complex sociotechnical origins, institutions with long-standing as well as recent EHR implementations should build a robust infrastructure to monitor and learn from them.
Keywords: Electronic Health Records; human factors; medical errors; patients safety; reporting systems; sociotechnical.
Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Similar articles
-
Assessment of Health Information Technology-Related Outpatient Diagnostic Delays in the US Veterans Affairs Health Care System: A Qualitative Study of Aggregated Root Cause Analysis Data.JAMA Netw Open. 2020 Jun 1;3(6):e206752. doi: 10.1001/jamanetworkopen.2020.6752. JAMA Netw Open. 2020. PMID: 32584406 Free PMC article.
-
Electronic health record-related safety concerns: a cross-sectional survey.J Healthc Risk Manag. 2014;34(1):14-26. doi: 10.1002/jhrm.21146. J Healthc Risk Manag. 2014. PMID: 25070253
-
Safety huddles to proactively identify and address electronic health record safety.J Am Med Inform Assoc. 2017 Mar 1;24(2):261-267. doi: 10.1093/jamia/ocw153. J Am Med Inform Assoc. 2017. PMID: 28031286 Free PMC article.
-
A Sociotechnical Framework for Safety-Related Electronic Health Record Research Reporting: The SAFER Reporting Framework.Ann Intern Med. 2020 Jun 2;172(11 Suppl):S92-S100. doi: 10.7326/M19-0879. Ann Intern Med. 2020. PMID: 32479184 Review.
-
Measuring and improving patient safety through health information technology: The Health IT Safety Framework.BMJ Qual Saf. 2016 Apr;25(4):226-32. doi: 10.1136/bmjqs-2015-004486. Epub 2015 Sep 14. BMJ Qual Saf. 2016. PMID: 26369894 Free PMC article. Review.
Cited by
-
Perceptions of hospital electronic health record (EHR) training, support, and patient safety by staff position and tenure.BMC Health Serv Res. 2024 Aug 20;24(1):955. doi: 10.1186/s12913-024-11322-3. BMC Health Serv Res. 2024. PMID: 39164672 Free PMC article.
-
Implementation of a health information technology safety classification system in the Veterans Health Administration's Informatics Patient Safety Office.J Am Med Inform Assoc. 2024 Jun 20;31(7):1588-1595. doi: 10.1093/jamia/ocae107. J Am Med Inform Assoc. 2024. PMID: 38758666
-
Development of minimum data set and dashboard for monitoring adverse events in radiology departments.Heliyon. 2024 Apr 24;10(9):e30054. doi: 10.1016/j.heliyon.2024.e30054. eCollection 2024 May 15. Heliyon. 2024. PMID: 38707457 Free PMC article.
-
Assessing the Usability and Feasibility of Digital Assistant Tools for Direct Support Professionals: Participatory Design and Pilot-Testing.JMIR Hum Factors. 2024 Apr 25;11:e51612. doi: 10.2196/51612. JMIR Hum Factors. 2024. PMID: 38662420 Free PMC article.
-
Operational disruption in healthcare associated with software functionality issue due to software security patching: a case report.Front Digit Health. 2024 Mar 14;6:1367431. doi: 10.3389/fdgth.2024.1367431. eCollection 2024. Front Digit Health. 2024. PMID: 38550716 Free PMC article.
References
-
- Institute of Medicine (IOM). Crossing the quality chasm a new health system for the 21st century. The National Academy Press, 2001 - PubMed
-
- Balka E, Doyle-Waters M, Lecznarowicz D, et al. . Technology, governance and patient safety: systems issues in technology and patient safety. Int J Med Inform 2007;76(Suppl 1):S35–47 - PubMed