Cryptogenic stroke and underlying atrial fibrillation
- PMID: 24963567
- DOI: 10.1056/NEJMoa1313600
Cryptogenic stroke and underlying atrial fibrillation
Abstract
Background: Current guidelines recommend at least 24 hours of electrocardiographic (ECG) monitoring after an ischemic stroke to rule out atrial fibrillation. However, the most effective duration and type of monitoring have not been established, and the cause of ischemic stroke remains uncertain despite a complete diagnostic evaluation in 20 to 40% of cases (cryptogenic stroke). Detection of atrial fibrillation after cryptogenic stroke has therapeutic implications.
Methods: We conducted a randomized, controlled study of 441 patients to assess whether long-term monitoring with an insertable cardiac monitor (ICM) is more effective than conventional follow-up (control) for detecting atrial fibrillation in patients with cryptogenic stroke. Patients 40 years of age or older with no evidence of atrial fibrillation during at least 24 hours of ECG monitoring underwent randomization within 90 days after the index event. The primary end point was the time to first detection of atrial fibrillation (lasting >30 seconds) within 6 months. Among the secondary end points was the time to first detection of atrial fibrillation within 12 months. Data were analyzed according to the intention-to-treat principle.
Results: By 6 months, atrial fibrillation had been detected in 8.9% of patients in the ICM group (19 patients) versus 1.4% of patients in the control group (3 patients) (hazard ratio, 6.4; 95% confidence interval [CI], 1.9 to 21.7; P<0.001). By 12 months, atrial fibrillation had been detected in 12.4% of patients in the ICM group (29 patients) versus 2.0% of patients in the control group (4 patients) (hazard ratio, 7.3; 95% CI, 2.6 to 20.8; P<0.001).
Conclusions: ECG monitoring with an ICM was superior to conventional follow-up for detecting atrial fibrillation after cryptogenic stroke. (Funded by Medtronic; CRYSTAL AF ClinicalTrials.gov number, NCT00924638.).
Comment in
-
Heart-rhythm monitoring for evaluation of cryptogenic stroke.N Engl J Med. 2014 Jun 26;370(26):2532-3. doi: 10.1056/NEJMe1405046. N Engl J Med. 2014. PMID: 24963573 No abstract available.
-
Atrial fibrillation. Cryptogenic stroke--can we abandon this apologetic diagnosis?Nat Rev Cardiol. 2014 Sep;11(9):504-5. doi: 10.1038/nrcardio.2014.111. Epub 2014 Jul 29. Nat Rev Cardiol. 2014. PMID: 25072906
-
Cryptogenic stroke and atrial fibrillation.N Engl J Med. 2014 Sep 25;371(13):1259. doi: 10.1056/NEJMc1409495. N Engl J Med. 2014. PMID: 25251622 No abstract available.
-
Cryptogenic stroke and atrial fibrillation.N Engl J Med. 2014 Sep 25;371(13):1259-60. doi: 10.1056/NEJMc1409495. N Engl J Med. 2014. PMID: 25251623 No abstract available.
-
Cryptogenic stroke and atrial fibrillation.N Engl J Med. 2014 Sep 25;371(13):1261. doi: 10.1056/NEJMc1409495. N Engl J Med. 2014. PMID: 25259387 No abstract available.
Similar articles
-
Uncovering Atrial Fibrillation Beyond Short-Term Monitoring in Cryptogenic Stroke Patients: Three-Year Results From the Cryptogenic Stroke and Underlying Atrial Fibrillation Trial.Circ Arrhythm Electrophysiol. 2016 Jan;9(1):e003333. doi: 10.1161/CIRCEP.115.003333. Circ Arrhythm Electrophysiol. 2016. PMID: 26763225 Clinical Trial.
-
Implantable cardiac monitors to detect atrial fibrillation after cryptogenic stroke: a systematic review and economic evaluation.Health Technol Assess. 2020 Jan;24(5):1-184. doi: 10.3310/hta24050. Health Technol Assess. 2020. PMID: 31944175 Free PMC article.
-
Atrial fibrillation in patients with cryptogenic stroke.N Engl J Med. 2014 Jun 26;370(26):2467-77. doi: 10.1056/NEJMoa1311376. N Engl J Med. 2014. PMID: 24963566 Clinical Trial.
-
The efficacy and safety of insertable cardiac monitor on atrial fibrillation detection in patients with ischemic stroke: a systematic review and meta-analysis.J Neurol. 2022 May;269(5):2338-2345. doi: 10.1007/s00415-021-10903-0. Epub 2021 Nov 20. J Neurol. 2022. PMID: 34802068 Review.
-
Identification of Covert Atrial Fibrillation in Cryptogenic Ischemic Stroke: Current Clinical Practice in Japan.J Stroke Cerebrovasc Dis. 2016 Aug;25(8):1829-37. doi: 10.1016/j.jstrokecerebrovasdis.2016.05.012. Epub 2016 Jun 6. J Stroke Cerebrovasc Dis. 2016. PMID: 27282299 Review.
Cited by
-
Long-term Monitoring to Detect Risk of Sudden Cardiac Death in Inherited Arrhythmia Patients.CJC Open. 2024 May 21;6(9):1066-1074. doi: 10.1016/j.cjco.2024.05.007. eCollection 2024 Sep. CJC Open. 2024. PMID: 39525816 Free PMC article.
-
MR-proANP levels in Acute ischemic stroke and clinical outcomes: a systematic review and meta-analysis.Neurosurg Rev. 2024 Nov 5;47(1):835. doi: 10.1007/s10143-024-03073-w. Neurosurg Rev. 2024. PMID: 39496843
-
Uncovering the Risks and Benefits of Patent Foramen Ovale (PFO) Closure in Cryptogenic Stroke: A Case Study.Cureus. 2024 Oct 1;16(10):e70595. doi: 10.7759/cureus.70595. eCollection 2024 Oct. Cureus. 2024. PMID: 39483586 Free PMC article.
-
MicroRNAs and other biomarkers of atrial fibrillation in ischemic stroke patients.Medicine (Baltimore). 2024 Oct 25;103(43):e40165. doi: 10.1097/MD.0000000000040165. Medicine (Baltimore). 2024. PMID: 39470526 Free PMC article.
-
A Comprehensive Review of Cryptogenic Stroke and Atrial Fibrillation: Real-World Insights Into the Role of Insertable Cardiac Monitors.Cureus. 2024 Sep 28;16(9):e70369. doi: 10.7759/cureus.70369. eCollection 2024 Sep. Cureus. 2024. PMID: 39469374 Free PMC article. Review.
Publication types
MeSH terms
Substances
Associated data
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical