Reverse Redistribution in Myocardial Perfusion Imaging: Revisited with 64-slice MDCT

Nucl Med Mol Imaging. 2010 Jun;44(2):154-6. doi: 10.1007/s13139-010-0019-y. Epub 2010 Apr 21.

Abstract

The authors report myocardial perfusion imaging of a patient showing reverse redistribution (RR) and a 64-slice multidetector-row computed tomography (MDCT) with corresponding findings. The patient had subendocardial myocardial infarction (MI) with positive electrocardiogram (EKG) findings and elevated levels of cardiac isoenzymes. Experiencing this case emphasizes the importance of complementary correlation of a new diagnostic modality that helps us to understand the nature of RR.

Keywords: 64-slice multidetector-row CT; Myocardial perfusion imaging; Reverse redistribution; Subendocardial MI.