Valve migration into the left ventricular outflow tract managed by coaxial double-valve alignment

JACC Cardiovasc Interv. 2014 Jul;7(7):822-4. doi: 10.1016/j.jcin.2013.10.029.
No abstract available

Keywords: computed tomography (CT); embolization; hemodynamic status; percutaneous aortic valve replacement.

Publication types

  • Case Reports
  • Video-Audio Media

MeSH terms

  • Aged, 80 and over
  • Aortic Valve Stenosis / diagnosis
  • Aortic Valve Stenosis / therapy*
  • Cardiac Catheterization / adverse effects*
  • Cardiac Catheterization / instrumentation
  • Female
  • Foreign-Body Migration / diagnosis
  • Foreign-Body Migration / etiology
  • Foreign-Body Migration / therapy*
  • Heart Valve Prosthesis Implantation / adverse effects*
  • Heart Valve Prosthesis Implantation / instrumentation
  • Heart Valve Prosthesis Implantation / methods
  • Heart Valve Prosthesis*
  • Heart Ventricles* / diagnostic imaging
  • Humans
  • Prosthesis Design
  • Severity of Illness Index
  • Tomography, X-Ray Computed
  • Treatment Outcome