Effect of ProTaper Universal, Endoflare, Revo-S, HyFlex coronal flaring instruments, and Gates Glidden drills on crack formation

J Endod. 2014 Oct;40(10):1681-3. doi: 10.1016/j.joen.2014.06.004. Epub 2014 Aug 12.

Abstract

Introduction: The aim of the present study was to evaluate crack formation after flaring root canals with Gates Glidden drills and ProTaper Universal (SX; Dentsply Maillefer, Ballaigues, Switzerland), Endoflare (MicroMega, Besançon, France), Revo-S (MicroMega), and HyFlex (Coltene-Whaledent, Allstetten, Switzerland) flaring instruments.

Methods: One-hundred eight mandibular molars were selected. Eighteen teeth were left unprepared to serve as negative controls; the experimental groups consisted of the mesiobuccal and mesiolingual root canals of the remaining 90 teeth, which were instrumented with the following coronal flaring instruments: Gates Glidden drills and ProTaper Universal SX, Endoflare, Revo-S SC1, and HyFlex 25.08 instruments. All roots were then sectioned perpendicular to the long axis at 1, 2, 3, 4, 6, and 8 mm from the cementoenamel junction. The sections were inspected under a stereomicroscope, and any crack formations were recorded. The data were analyzed using the chi-square test (P = .05).

Results: The Gates Glidden drills resulted in a higher rate of crack formation than that noted in the control group (P < .05). Flaring of the root canals using the ProTaper Universal, Endoflare, Revo-S, and HyFlex instruments resulted in crack formation similar to that of the control group (P > .05).

Conclusions: The use of the Gates Glidden drills resulted in the formation of the most cracks. However, the results for the ProTaper Universal, Endoflare, Revo-S, and HyFlex flaring instruments were similar to those of the control group in terms of crack formation.

Keywords: Coronal flaring; Endoflare; Gates Glidden; HyFlex; ProTaper Universal; Revo-S; cracks; dentinal damage.

MeSH terms

  • Dental Alloys / chemistry
  • Dental Pulp Cavity / injuries*
  • Dentin / injuries*
  • Equipment Design
  • Humans
  • Materials Testing
  • Molar / injuries
  • Nickel / chemistry
  • Root Canal Irrigants / administration & dosage
  • Root Canal Preparation / instrumentation*
  • Rotation
  • Sodium Hypochlorite / administration & dosage
  • Titanium / chemistry
  • Torque

Substances

  • Dental Alloys
  • Root Canal Irrigants
  • titanium nickelide
  • Nickel
  • Titanium
  • Sodium Hypochlorite