Accuracy of coronary CT angiography using a submillisievert fraction of radiation exposure: comparison with invasive coronary angiography
- PMID: 25145520
- DOI: 10.1016/j.jacc.2014.04.079
Accuracy of coronary CT angiography using a submillisievert fraction of radiation exposure: comparison with invasive coronary angiography
Abstract
Background: Coronary computed tomography angiography (CTA) is increasingly being used for evaluation of coronary artery disease (CAD). As a result of the widely reported potential of carcinogenic risk from x-ray based examinations, many strategies have been developed for dose reduction with CTA.
Objectives: The purpose of this study was to assess the diagnostic accuracy of CTA acquired with a submillisievert fraction of effective radiation dose reconstructed with a model-based iterative reconstruction (MBIR) using invasive coronary angiography (ICA) as a standard of reference.
Methods: In 36 patients (body mass index range 17 to 39 kg/m(2)) undergoing ICA for CAD evaluation, a CTA was acquired using very low tube voltage (80 to 100 kV) and current (150 to 210 mA) and was reconstructed with MBIR. CAD (defined as ≥50% luminal narrowing) was assessed on CTA and on ICA.
Results: CTA resulted in an estimated radiation dose exposure of 0.29 ± 0.12 mSv (range 0.16 to 0.53 mSv), yielding 96.9% (436 of 450) interpretable segments. On an intention-to-diagnose basis, no segment was excluded, and vessels with at least 1 nonevaluable segment and no further finding were classified as false positive. This resulted in a sensitivity, specificity, positive, and negative predictive value and accuracy of 100%, 74%, 77%, 100%, and 86% per patient and 85%, 86%, 56%, 96%, and 85% per vessel, respectively.
Conclusions: The use of MBIR reconstruction allows accurate noninvasive diagnosis of CAD with CTA at a submillisievert fraction of effective radiation dose comparable with a chest x-ray in 2 views.
Keywords: computed tomography; coronary CT angiography; iterative reconstruction; low radiation exposure; submillisievert.
Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Comment in
-
Minimizing CT angiography radiation burden while maintaining accuracy through noise reduction: is lower always better?J Am Coll Cardiol. 2014 Aug 26;64(8):781-3. doi: 10.1016/j.jacc.2014.04.078. J Am Coll Cardiol. 2014. PMID: 25145521 No abstract available.
Similar articles
-
Coronary CT angiography with 80 kV tube voltage and low iodine concentration contrast agent in patients with low body weight.J Cardiovasc Comput Tomogr. 2016 Jul-Aug;10(4):322-6. doi: 10.1016/j.jcct.2016.06.003. Epub 2016 Jun 15. J Cardiovasc Comput Tomogr. 2016. PMID: 27357327
-
Iterative reconstruction to preserve image quality and diagnostic accuracy at reduced radiation dose in coronary CT angiography: an intraindividual comparison.JACC Cardiovasc Imaging. 2013 Dec;6(12):1239-49. doi: 10.1016/j.jcmg.2013.08.008. Epub 2013 Oct 23. JACC Cardiovasc Imaging. 2013. PMID: 24269265
-
Accuracy of prospectively ECG-triggered very low-dose coronary dual-source CT angiography using iterative reconstruction for the detection of coronary artery stenosis: comparison with invasive catheterization.Eur Heart J Cardiovasc Imaging. 2014 Nov;15(11):1238-45. doi: 10.1093/ehjci/jeu113. Epub 2014 Jun 17. Eur Heart J Cardiovasc Imaging. 2014. PMID: 24939952
-
Head-to-head comparison of prospectively triggered vs retrospectively gated coronary computed tomography angiography: Meta-analysis of diagnostic accuracy, image quality, and radiation dose.Am Heart J. 2013 Feb;165(2):154-63.e3. doi: 10.1016/j.ahj.2012.10.026. Epub 2012 Nov 26. Am Heart J. 2013. PMID: 23351817 Review.
-
Coronary computed tomography angiography: a new wave of cardiac imaging.Intern Med J. 2012 Oct;42 Suppl 5:22-9. doi: 10.1111/j.1445-5994.2012.02901.x. Intern Med J. 2012. PMID: 23035678 Review.
Cited by
-
Diagnostic performance of deep learning-based vessel extraction and stenosis detection on coronary computed tomography angiography for coronary artery disease: a multi-reader multi-case study.Radiol Med. 2023 Mar;128(3):307-315. doi: 10.1007/s11547-023-01606-9. Epub 2023 Feb 17. Radiol Med. 2023. PMID: 36800112
-
Coronary Computer Tomography Angiography in 2021-Acquisition Protocols, Tips and Tricks and Heading beyond the Possible.Diagnostics (Basel). 2021 Jun 10;11(6):1072. doi: 10.3390/diagnostics11061072. Diagnostics (Basel). 2021. PMID: 34200866 Free PMC article. Review.
-
Diagnostic performance of deep learning-based vascular extraction and stenosis detection technique for coronary artery disease.Br J Radiol. 2020 Sep 1;93(1113):20191028. doi: 10.1259/bjr.20191028. Epub 2020 Mar 25. Br J Radiol. 2020. PMID: 32101464 Free PMC article.
-
Coronary artery volume index: a novel CCTA-derived predictor for cardiovascular events.Int J Cardiovasc Imaging. 2020 Apr;36(4):713-722. doi: 10.1007/s10554-019-01750-2. Epub 2020 Jan 1. Int J Cardiovasc Imaging. 2020. PMID: 31894527
-
Cardiac CT: Technological Advances in Hardware, Software, and Machine Learning Applications.Curr Cardiovasc Imaging Rep. 2018 Aug;11:19. doi: 10.1007/s12410-018-9459-z. Epub 2018 Jun 29. Curr Cardiovasc Imaging Rep. 2018. PMID: 31656551 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials
Miscellaneous