Coupling heat and chemical tracer experiments for estimating heat transfer parameters in shallow alluvial aquifers

J Contam Hydrol. 2014 Nov 15:169:90-99. doi: 10.1016/j.jconhyd.2014.08.001. Epub 2014 Aug 12.

Abstract

Geothermal energy systems, closed or open, are increasingly considered for heating and/or cooling buildings. The efficiency of such systems depends on the thermal properties of the subsurface. Therefore, feasibility and impact studies performed prior to their installation should include a field characterization of thermal properties and a heat transfer model using parameter values measured in situ. However, there is a lack of in situ experiments and methodology for performing such a field characterization, especially for open systems. This study presents an in situ experiment designed for estimating heat transfer parameters in shallow alluvial aquifers with focus on the specific heat capacity. This experiment consists in simultaneously injecting hot water and a chemical tracer into the aquifer and monitoring the evolution of groundwater temperature and concentration in the recovery well (and possibly in other piezometers located down gradient). Temperature and concentrations are then used for estimating the specific heat capacity. The first method for estimating this parameter is based on a modeling in series of the chemical tracer and temperature breakthrough curves at the recovery well. The second method is based on an energy balance. The values of specific heat capacity estimated for both methods (2.30 and 2.54MJ/m(3)/K) for the experimental site in the alluvial aquifer of the Meuse River (Belgium) are almost identical and consistent with values found in the literature. Temperature breakthrough curves in other piezometers are not required for estimating the specific heat capacity. However, they highlight that heat transfer in the alluvial aquifer of the Meuse River is complex and contrasted with different dominant process depending on the depth leading to significant vertical heat exchange between upper and lower part of the aquifer. Furthermore, these temperature breakthrough curves could be included in the calibration of a complex heat transfer model for estimating the entire set of heat transfer parameters and their spatial distribution by inverse modeling.

Keywords: Aquifer thermal energy storage; Heat tracer test; Heat transfer; Shallow geothermal energy; Solute transport; Very low temperature geothermy.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Belgium
  • Environmental Monitoring
  • Geothermal Energy*
  • Groundwater / chemistry*
  • Hot Temperature*
  • Models, Theoretical