Comparison of automated breast volume scanning and hand- held ultrasound in the detection of breast cancer: an analysis of 5,566 patient evaluations

Asian Pac J Cancer Prev. 2014;15(21):9101-5. doi: 10.7314/apjcp.2014.15.21.9101.

Abstract

Background: The purpose of this study was to compare the accuracy and effectiveness of automated breast volume scanning (ABVS) and hand-held ultrasound (HHUS) in the detection of breast cancer in a large population group with a long-term follow-up, and to investigate whether different ultrasound systems may influence the estimation of cancer detection.

Materials and methods: Institutional review board approval was obtained for this retrospective study, and informed consent was waived. From September 2010 to August 2011, a total of 1,866 ABVS and 3,700 HHUS participants, who underwent these procedures at our institute, were included in this study. Cancers occurring during the study and subsequent follow-up were evaluated. The reference standard was a combination of histology and follow-up imaging (≥12 months). The recall rate, cancer detection yield, diagnostic accuracy, sensitivity, specificity, and positive (PPV) and negative (NPV) predictive values were calculated with exact 95% confidence intervals.

Results: The recall rate was 2.57 per 1,000 (48/1,866) for ABVS and 3.57 per 1,000 (132/3,700) for HHUS, with ? significant difference (p=0.048). The cancer detection yield was 3.8 per 1,000 for ABVS and 2.7 per 1,000 for HHUS. The diagnostic accuracy was 97.7% for ABVS and 96.5% for HHUS with statistical significance (p=0.018). The specificity of ABVS and HHUS were 97.8%, 96.7%, respectively (p=0.022).

Conclusions: ABVS shows a comparable diagnostic performance to HHUS. ABVS is an effective supplemental tool for mammography in breast cancer detection in a large population.

Publication types

  • Comparative Study

MeSH terms

  • Adenocarcinoma, Mucinous / diagnostic imaging*
  • Adenocarcinoma, Mucinous / pathology
  • Adult
  • Aged
  • Aged, 80 and over
  • Breast / pathology*
  • Breast Neoplasms / diagnostic imaging*
  • Breast Neoplasms / pathology
  • Carcinoma, Ductal, Breast / diagnostic imaging*
  • Carcinoma, Ductal, Breast / pathology
  • Carcinoma, Intraductal, Noninfiltrating / diagnostic imaging*
  • Carcinoma, Intraductal, Noninfiltrating / pathology
  • Female
  • Follow-Up Studies
  • Humans
  • Image Interpretation, Computer-Assisted
  • Middle Aged
  • Miniaturization
  • Neoplasm Invasiveness
  • Neoplasm Staging
  • Pattern Recognition, Automated*
  • Prognosis
  • Retrospective Studies
  • Sensitivity and Specificity
  • Tumor Burden
  • Ultrasonography, Mammary / instrumentation
  • Ultrasonography, Mammary / methods*
  • Young Adult