Technical feasibility and intermediate outcomes of using a handcrafted, area-preserving, bifurcated Y-graft modification of the Fontan procedure

J Thorac Cardiovasc Surg. 2015 Jan;149(1):239-45.e1. doi: 10.1016/j.jtcvs.2014.08.058. Epub 2014 Sep 16.

Abstract

Objectives: To demonstrate the technical feasibility and describe intermediate outcomes for the initial patients undergoing handcrafted, area-preserving, Y-graft modification of the Fontan procedure.

Methods: A retrospective review of a pilot study was undertaken to describe preoperative, intraoperative, and postoperative results.

Results: Six patients underwent successful procedures and remain alive 3 to 4 years later. The median age at operation was 3.3 years, and median weight was 13.2 kg. Five operations were done without cardiopulmonary bypass and no intraoperative pressure gradients were found. Five patients were extubated by postoperative day 1, Fontan pressures were 12 to 14 mm Hg, transpulmonary gradients were 6 to 8 mm Hg, and no renal or hepatic function abnormalities were found. Length of stay was 10 to 64 days. One patient required venovenous extracorporeal membrane oxygenation for previously undiagnosed plastic bronchitis (64-day stay); another required reoperation for an incidentally diagnosed aortic thrombus (44-day stay). One patient had occlusion of a Y-graft limb noted on magnetic resonance imaging follow-up at 3 months. Catheterization showed excellent hemodynamic parameters and no Fontan obstruction. Occlusion was believed to be due to right-sided pulmonary arteriovenous malformations and widely discrepant flow (80%) to the right lung leading to low flow in the left limb.

Conclusions: The area-preserving, bifurcated Y-graft Fontan modification is technically feasible and shows excellent intermediate outcomes. Additional study is required to determine whether the advantages seen in the computational models will be realized in patients over the long-term, and to optimize patient selection for each of the various Fontan options now available.

Publication types

  • Observational Study
  • Research Support, Non-U.S. Gov't
  • Video-Audio Media

MeSH terms

  • Blood Vessel Prosthesis Implantation / adverse effects
  • Blood Vessel Prosthesis Implantation / instrumentation*
  • Blood Vessel Prosthesis Implantation / methods
  • Blood Vessel Prosthesis*
  • Child, Preschool
  • Feasibility Studies
  • Fontan Procedure / adverse effects
  • Fontan Procedure / instrumentation*
  • Fontan Procedure / methods
  • Heart Defects, Congenital / diagnosis
  • Heart Defects, Congenital / physiopathology
  • Heart Defects, Congenital / surgery*
  • Hemodynamics
  • Humans
  • Length of Stay
  • Magnetic Resonance Angiography
  • Pilot Projects
  • Postoperative Complications / therapy
  • Prosthesis Design
  • Pulmonary Artery / diagnostic imaging
  • Pulmonary Artery / physiopathology
  • Pulmonary Artery / surgery*
  • Retrospective Studies
  • Time Factors
  • Tomography, X-Ray Computed
  • Treatment Outcome
  • Vena Cava, Inferior / diagnostic imaging
  • Vena Cava, Inferior / physiopathology
  • Vena Cava, Inferior / surgery*