Skip to main page content
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2015 Mar;84(3):418-423.
doi: 10.1016/j.ejrad.2014.11.037. Epub 2014 Dec 15.

Drug-eluting Versus Plain Balloon Angioplasty for the Treatment of Failing Dialysis Access: Final Results and Cost-Effectiveness Analysis From a Prospective Randomized Controlled Trial (NCT01174472)

Affiliations
Randomized Controlled Trial

Drug-eluting Versus Plain Balloon Angioplasty for the Treatment of Failing Dialysis Access: Final Results and Cost-Effectiveness Analysis From a Prospective Randomized Controlled Trial (NCT01174472)

Panagiotis M Kitrou et al. Eur J Radiol. .

Abstract

Objective: To report the final results and cost-effectiveness analysis of a prospective randomized controlled trial investigating drug-eluting balloon (DEB) versus plain balloon angioplasty (BA) for the treatment of failing dialysis access (NCT01174472).

Methods: 40 patients were randomized to angioplasty with either DEB (n=20) or BA (n=20) for treatment of significant venous stenosis causing a failing dialysis access. Both arteriovenous fistulas (AVF) and synthetic arteriovenous grafts (AVG) were included. Angiographic follow up was scheduled every two months. Primary endpoints were technical success and target lesion primary patency at 1 year. Cumulative and survival analysis was performed. Incremental net benefit (INB) and incremental cost effectiveness ratio (ICER) were calculated and the cost-effectiveness acceptability curve (CEAC) was drawn.

Results: Baseline variables were equally distributed between the two groups. At 1 year, cumulative target lesion primary patency was significantly higher after DEB application (35% vs. 5% after BA, p<0.001). Overall, median primary patency was 0.64 years in case of DEB vs. 0.36 years in case of BA (p=0.0007; unadjusted HR=0.27 [95%CI: 0.13-0.58]; Cox adjusted HR=0.23 [95%CI: 0.10-0.50]). ICER was 2198 Euros (€) per primary patency year of dialysis access gained. INB was 1068€ (95%CI: 31-2105€) for a willingness-to-pay (WTP) threshold of 5000€ (corresponding acceptability probability >97%).

Conclusion: DEB angioplasty may be a cost-effective option that significantly improves patency after angioplasty of venous stenoses of failing vascular dialysis access. Further large-scale randomized trials are warranted.

Keywords: Dialysis; Drug-eluting balloons; Neointimal hyperplasia; Restenosis.

Similar articles

See all similar articles

Cited by 10 articles

See all "Cited by" articles

Publication types

Associated data

Feedback