Silent ischemic brain lesions after transcatheter aortic valve replacement: lesion distribution and predictors

Clin Res Cardiol. 2015 May;104(5):430-8. doi: 10.1007/s00392-014-0798-8. Epub 2015 Jan 18.

Abstract

Aims: Silent ischemic brain lesions and ischemic stroke are known complications of transcatheter aortic valve replacement (TAVR). We aimed to investigate the occurrence and distribution of TAVR-related silent ischemic brain lesions using diffusion-weighted magnetic resonance imaging (DWI).

Methods: Consecutive patients with severe aortic valve stenosis treated with TAVR underwent cerebral DWI within 5 days after the index procedure. DWI scans were analyzed for the occurrence and distribution of new ischemic lesions post-TAVR.

Results: Forty-two patients were enrolled in this study. After TAVR, a total of 276 new cerebral ischemic lesions were detected in 38 (90 %) patients, with a median of 4.5 (interquartile range 2.0-7.0) lesions per patient. A total of 129 (47 %) lesions were detected in the cortical regions, 97 (35 %) in the subcortical regions, and 50 (18 %) in the cerebellum or brainstem. The median lesion volume was 20.2 µl (10.0, 42.7) and the total ischemic lesion volume was 132.3 µl (42.8, 336.9). The new ischemic brain lesions were clinically silent in 37 (97 %) patients; the other patient had a transient ischemic attack. Age (B = 0.528, p = 0.015), hyperlipidaemia (B = 5.809, p = 0.028) and post-dilatation of the implanted prosthesis (B = 7.196, p = 0.029) were independently associated with the number of post-TAVR cerebral DWI lesions. In addition, peak transaortic gradient was independently associated with post-procedural total infarct volume.

Conclusion: Clinically silent cerebral infarcts occurred in 90 % of patients following TAVR, most of which were small (<20 μl) and located in the cortical regions of the cerebral hemispheres. An independent association was found between age, hyperlipidaemia and balloon post-dilatation and the number of post-TAVR ischemic brain lesions. Only peak transaortic gradient was independently associated with post-procedural total infarct volume.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Valve Stenosis / surgery*
  • Brain Ischemia / diagnosis*
  • Brain Ischemia / epidemiology
  • Brain Ischemia / etiology*
  • Diffusion Magnetic Resonance Imaging* / methods
  • Female
  • Germany / epidemiology
  • Humans
  • Incidence
  • Intracranial Embolism / diagnosis*
  • Intracranial Embolism / epidemiology
  • Intracranial Embolism / etiology*
  • Male
  • Predictive Value of Tests
  • Prospective Studies
  • Risk Assessment
  • Risk Factors
  • Sensitivity and Specificity
  • Transcatheter Aortic Valve Replacement / adverse effects*