Intraoperative fluorescence-based enhanced reality laparoscopic real-time imaging to assess bowel perfusion at the anastomotic site in an experimental model
- PMID: 25627131
- DOI: 10.1002/bjs.9725
Intraoperative fluorescence-based enhanced reality laparoscopic real-time imaging to assess bowel perfusion at the anastomotic site in an experimental model
Abstract
Background: Fluorescence videography is a promising technique for assessing bowel perfusion. Fluorescence-based enhanced reality (FLER) is a novel concept, in which a dynamic perfusion cartogram, generated by computer analysis, is superimposed on to real-time laparoscopic images. The aim of this experimental study was to assess the accuracy of FLER in detecting differences in perfusion in a small bowel resection-anastomosis model.
Methods: A small bowel ischaemic segment was created laparoscopically in 13 pigs. Animals were allocated to having anastomoses performed at either low perfusion (25 per cent; n = 7) or high perfusion (75 per cent; n = 6), as determined by FLER analysis. Capillary lactate levels were measured in blood samples obtained by serosal puncturing in the ischaemic area, resection lines and vascularized areas. Pathological inflammation scoring of the anastomosis was carried out.
Results: Lactate levels in the ischaemic area (mean(s.d.) 5·6(2·8) mmol/l) were higher than those in resection lines at 25 per cent perfusion (3·7(1·7) mmol/l; P = 0·010) and 75 per cent perfusion (2·9(1·3) mmol/l; P < 0·001), and higher than levels in vascular zones (2·5(1·0) mmol/l; P < 0·001). Lactate levels in resection lines with 75 per cent perfusion were lower than those in lines with 25 per cent perfusion (P < 0·001), and similar to those in vascular zones (P = 0·188). Levels at resection lines with 25 per cent perfusion were higher than those in vascular zones (P = 0·001). Mean(s.d.) global inflammation scores were higher in the 25 per cent perfusion group compared with the 75 per cent perfusion group for mucosa/submucosa (2·1(0·4) versus 1·2(0·4); P = 0·003) and serosa (1·8(0·4) versus 0·8(0·8); P = 0·014). A ratio of preanastomotic lactate levels in the ischaemic area relative to the resection lines of 2 or less was predictive of a more severe inflammation score.
Conclusion: In an experimental model, FLER appeared accurate in discriminating bowel perfusion levels. Surgical relevance Clinical assessment has limited accuracy in evaluating bowel perfusion before anastomosis. Fluorescence videography estimates intestinal perfusion based on the fluorescence intensity of injected fluorophores, which is proportional to bowel vascularization. However, evaluation of fluorescence intensity remains a static and subjective measure. Fluorescence-based enhanced reality (FLER) is a dynamic fluorescence videography technique integrating near-infrared endoscopy and specific software. The software generates a virtual perfusion cartogram based on time to peak fluorescence, which can be superimposed on to real-time laparoscopic images. This experimental study demonstrates the accuracy of FLER in detecting differences in bowel perfusion in a survival model of laparoscopic small bowel resection-anastomosis, based on biochemical and histopathological data. It is concluded that real-time imaging of bowel perfusion is easy to use and accurate, and should be translated into clinical use.
© 2015 BJS Society Ltd. Published by John Wiley & Sons Ltd.
Similar articles
-
Simultaneous computer-assisted assessment of mucosal and serosal perfusion in a model of segmental colonic ischemia.Surg Endosc. 2020 Nov;34(11):4818-4827. doi: 10.1007/s00464-019-07258-z. Epub 2019 Nov 18. Surg Endosc. 2020. PMID: 31741157
-
Enhanced-reality video fluorescence: a real-time assessment of intestinal viability.Ann Surg. 2014 Apr;259(4):700-7. doi: 10.1097/SLA.0b013e31828d4ab3. Ann Surg. 2014. PMID: 23532109
-
Real-time navigation by fluorescence-based enhanced reality for precise estimation of future anastomotic site in digestive surgery.Surg Endosc. 2014 Nov;28(11):3108-18. doi: 10.1007/s00464-014-3592-9. Epub 2014 Jun 10. Surg Endosc. 2014. PMID: 24912446
-
Bowel injury as a complication of laparoscopy.Br J Surg. 2004 Oct;91(10):1253-8. doi: 10.1002/bjs.4716. Br J Surg. 2004. PMID: 15376204 Review.
-
Intraoperative augmented reality for laparoscopic colorectal surgery by intraoperative near-infrared fluorescence imaging and optical coherence tomography.Minerva Chir. 2010 Aug;65(4):451-62. Minerva Chir. 2010. PMID: 20802433 Review.
Cited by
-
A feasibility study assessing quantitative indocyanine green angiographic predictors of reconstructive complications following nipple-sparing mastectomy.JPRAS Open. 2024 Jan 26;40:32-47. doi: 10.1016/j.jpra.2024.01.012. eCollection 2024 Jun. JPRAS Open. 2024. PMID: 38425697 Free PMC article.
-
NIR ICG-Enhanced Fluorescence: A Quantitative Evaluation of Bowel Microperfusion and Its Relation to Central Perfusion in Colorectal Surgery.Cancers (Basel). 2023 Nov 22;15(23):5528. doi: 10.3390/cancers15235528. Cancers (Basel). 2023. PMID: 38067233 Free PMC article.
-
Intra-abdominal laparoscopic assessment of organs perfusion using imaging photoplethysmography.Surg Endosc. 2023 Nov;37(11):8919-8929. doi: 10.1007/s00464-023-10506-y. Epub 2023 Oct 23. Surg Endosc. 2023. PMID: 37872427
-
Application of indocyanine green in surgery: A review of current evidence and implementation in trauma patients.World J Gastrointest Surg. 2023 May 27;15(5):757-775. doi: 10.4240/wjgs.v15.i5.757. World J Gastrointest Surg. 2023. PMID: 37342859 Free PMC article. Review.
-
Real-time quantification of intestinal perfusion and arterial versus venous occlusion using laser speckle contrast imaging in porcine model.Langenbecks Arch Surg. 2023 Mar 2;408(1):114. doi: 10.1007/s00423-023-02845-0. Langenbecks Arch Surg. 2023. PMID: 36859714
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
