Test-retest reliability of a new device for assessing ankle joint threshold to detect passive movement in healthy adults
- PMID: 25712530
- DOI: 10.1080/02640414.2014.1003589
Test-retest reliability of a new device for assessing ankle joint threshold to detect passive movement in healthy adults
Abstract
This study aimed to evaluate the test-retest reliability of a new device for assessing ankle joint kinesthesia. This device could measure the passive motion threshold of four ankle joint movements, namely plantarflexion, dorsiflexion, inversion and eversion. A total of 21 healthy adults, including 13 males and 8 females, participated in the study. Each participant completed two sessions on two separate days with 1-week interval. The sessions were administered by the same experimenter in the same laboratory. At least 12 trials (three successful trials in each of the four directions) were performed in each session. The mean values in each direction were calculated and analysed. The ICC values of test-retest reliability ranged from 0.737 (dorsiflexion) to 0.935 (eversion), whereas the SEM values ranged from 0.21° (plantarflexion) to 0.52° (inversion). The Bland-Altman plots showed that the reliability of plantarflexion-dorsiflexion was better than that of inversion-eversion. The results evaluated the reliability of the new device as fair to excellent. The new device for assessing kinesthesia could be used to examine the ankle joint kinesthesia.
Keywords: ankle joint; kinesthesia; new device; reliability.
Similar articles
-
A new device for assessing ankle dorsiflexion motion: reliability and validity.J Orthop Sports Phys Ther. 2011 Apr;41(4):274-80. doi: 10.2519/jospt.2011.3397. Epub 2011 Apr 1. J Orthop Sports Phys Ther. 2011. PMID: 21460462
-
Validity and reliability of a new ankle dorsiflexion measurement device.Prosthet Orthot Int. 2013 Aug;37(4):289-97. doi: 10.1177/0309364612465886. Epub 2012 Dec 4. Prosthet Orthot Int. 2013. PMID: 23211471
-
A simplified version of the weight-bearing ankle lunge test: description and test-retest reliability.Man Ther. 2014 Aug;19(4):355-9. doi: 10.1016/j.math.2014.03.008. Epub 2014 Apr 2. Man Ther. 2014. PMID: 24746162
-
Reliability of ankle goniometric measurements: a literature review.J Am Podiatr Med Assoc. 2005 Nov-Dec;95(6):564-72. doi: 10.7547/0950564. J Am Podiatr Med Assoc. 2005. PMID: 16291848 Review.
-
Differences in ankle joint complex range of motion as a function of age.Foot Ankle. 1993 May;14(4):215-22. doi: 10.1177/107110079301400407. Foot Ankle. 1993. PMID: 8359768 Review.
Cited by
-
Deficits in proprioception and strength may contribute to the impaired postural stability among individuals with functional ankle instability.Front Physiol. 2024 Mar 1;15:1342636. doi: 10.3389/fphys.2024.1342636. eCollection 2024. Front Physiol. 2024. PMID: 38496300 Free PMC article.
-
Tai Chi counteracts age-related somatosensation and postural control declines among older adults.J Exerc Sci Fit. 2024 Apr;22(2):152-158. doi: 10.1016/j.jesf.2024.02.004. Epub 2024 Feb 24. J Exerc Sci Fit. 2024. PMID: 38444520 Free PMC article.
-
Test-retest reliability of kinematic and kinetic parameters during dual-task stair walking in the elderly.Front Physiol. 2023 May 9;14:1177159. doi: 10.3389/fphys.2023.1177159. eCollection 2023. Front Physiol. 2023. PMID: 37228826 Free PMC article.
-
Balancing sensory inputs: somatosensory reweighting from proprioception to tactile sensation in maintaining postural stability among older adults with sensory deficits.Front Public Health. 2023 May 4;11:1165010. doi: 10.3389/fpubh.2023.1165010. eCollection 2023. Front Public Health. 2023. PMID: 37213635 Free PMC article.
-
Relationship of strength, joint kinesthesia, and plantar tactile sensation to dynamic and static postural stability among patients with anterior cruciate ligament reconstruction.Front Physiol. 2023 Jan 18;14:1112708. doi: 10.3389/fphys.2023.1112708. eCollection 2023. Front Physiol. 2023. PMID: 36744033 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources