Continuous-wavelet-transform analysis of the multifocal ERG waveform in glaucoma diagnosis
- PMID: 25850982
- DOI: 10.1007/s11517-015-1287-6
Continuous-wavelet-transform analysis of the multifocal ERG waveform in glaucoma diagnosis
Abstract
The vast majority of multifocal electroretinogram (mfERG) signal analyses to detect glaucoma study the signals' amplitudes and latencies. The purpose of this paper is to investigate application of wavelet analysis of mfERG signals in diagnosis of glaucoma. This analysis method applies the continuous wavelet transform (CWT) to the signals, using the real Morlet wavelet. CWT coefficients resulting from the scale of maximum correlation are used as inputs to a neural network, which acts as a classifier. mfERG recordings are taken from the eyes of 47 subjects diagnosed with chronic open-angle glaucoma and from those of 24 healthy subjects. The high sensitivity in the classification (0.894) provides reliable detection of glaucomatous sectors, while the specificity achieved (0.844) reflects accurate detection of healthy sectors. The results obtained in this paper improve on the previous findings reported by the authors using the same visual stimuli and database.
Keywords: Continuous wavelet transform; Glaucoma; Multifocal ERG; Neural network.
Similar articles
-
Glaucoma detection by wavelet-based analysis of the global flash multifocal electroretinogram.Med Eng Phys. 2010 Jul;32(6):617-22. doi: 10.1016/j.medengphy.2010.02.019. Epub 2010 Mar 29. Med Eng Phys. 2010. PMID: 20347378
-
Multifocal ERG wavelet packet decomposition applied to glaucoma diagnosis.Biomed Eng Online. 2011 May 17;10:37. doi: 10.1186/1475-925X-10-37. Biomed Eng Online. 2011. PMID: 21586161 Free PMC article.
-
Analysis of pattern electroretinogram signals of early primary open-angle glaucoma in discrete wavelet transform coefficients domain.Int Ophthalmol. 2019 Oct;39(10):2373-2383. doi: 10.1007/s10792-019-01077-w. Epub 2019 Feb 6. Int Ophthalmol. 2019. PMID: 30725244
-
Applications of the multifocal electroretinogram in the detection of glaucoma.Clin Exp Optom. 2011 May;94(3):247-58. doi: 10.1111/j.1444-0938.2010.00571.x. Epub 2011 Feb 16. Clin Exp Optom. 2011. PMID: 21323730 Review.
-
Electrophysiology and glaucoma: current status and future challenges.Cell Tissue Res. 2013 Aug;353(2):287-96. doi: 10.1007/s00441-013-1598-6. Epub 2013 Mar 24. Cell Tissue Res. 2013. PMID: 23525754 Review.
Cited by
-
Optimal Combination of Mother Wavelet and AI Model for Precise Classification of Pediatric Electroretinogram Signals.Sensors (Basel). 2023 Jun 22;23(13):5813. doi: 10.3390/s23135813. Sensors (Basel). 2023. PMID: 37447663 Free PMC article.
-
OculusGraphy: Signal Analysis of the Electroretinogram in a Rabbit Model of Endophthalmitis Using Discrete and Continuous Wavelet Transforms.Bioengineering (Basel). 2023 Jun 11;10(6):708. doi: 10.3390/bioengineering10060708. Bioengineering (Basel). 2023. PMID: 37370639 Free PMC article.
-
Novel Machine-Learning Based Framework Using Electroretinography Data for the Detection of Early-Stage Glaucoma.Front Neurosci. 2022 May 4;16:869137. doi: 10.3389/fnins.2022.869137. eCollection 2022. Front Neurosci. 2022. PMID: 35600610 Free PMC article.
-
Visual function tests for glaucoma practice - What is relevant?Indian J Ophthalmol. 2022 Mar;70(3):749-758. doi: 10.4103/ijo.IJO_1390_21. Indian J Ophthalmol. 2022. PMID: 35225508 Free PMC article. Review.
-
Diagnosis of multiple sclerosis using multifocal ERG data feature fusion.Inf Fusion. 2021 Dec;76:157-167. doi: 10.1016/j.inffus.2021.05.006. Inf Fusion. 2021. PMID: 34867127 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
