Rare use of twin Solitaire® stents in the double waffle-cone technique for endovascular treatment of a wide-necked bifurcation aneurysm

Interv Neuroradiol. 2015 Apr;21(2):167-70. doi: 10.1177/1591019915581998. Epub 2015 May 11.

Abstract

Endovascular treatment of wide-necked bifurcation aneurysms may be challenging. The waffle-cone technique can be used in these aneurysms in case of acute angulation between parent artery and distal artery of the aneurysm. Solitaire® stent (Ev3, Irvine, CA, USA) has the significant advantage of mitigating the potential complication risks. This study reports the second case in the literature in which endovascular treatment of a wide-necked bifurcation aneurysm with the double waffle-cone technique by using twin Solitaire® stents proved to be successful.

Keywords: Double waffle-cone technique; Solitaire® stent; acute angle; wide-necked bifurcation aneurysm.

Publication types

  • Case Reports

MeSH terms

  • Adult
  • Angiography, Digital Subtraction
  • Catheterization, Central Venous
  • Embolization, Therapeutic / methods
  • Endovascular Procedures / adverse effects
  • Endovascular Procedures / methods
  • Humans
  • Intracranial Aneurysm / diagnostic imaging
  • Intracranial Aneurysm / therapy*
  • Male
  • Middle Cerebral Artery / diagnostic imaging
  • Platelet Aggregation Inhibitors / therapeutic use
  • Stents* / adverse effects
  • Ticlopidine / therapeutic use
  • Treatment Outcome

Substances

  • Platelet Aggregation Inhibitors
  • Ticlopidine